Table 11 Recommended Torque Values for Pole/Wall Mount Bracket Locknuts
Item
Description
Torque
Note
1
Pole/wall mount bracket locknuts (x3)
16.3Nm or 12lbf-ft
—
To install the HM or RBM onto the mounted pole/wall mount bracket, refer to Figure 21, “Unit Installed
onto the Pole/Wall Mount Bracket” and follow these steps:
Note:
When installing the HM or RBM, orient it with the chassis cabling openings pointing downward.
Never mount the HM or RBM with the bottom facing up or to the side.
1.
Carefully fit the azimuth bracket into the pole/wall mount bracket.
2.
Place a washer on each bolt protruding through the top of the azimuth bracket from the pole/wall
mount bracket. Thread a locknut, by hand, onto the two bolts.
3.
Place a washer and then thread a locknut, by hand, onto the one bolt protruding through the
bottom of the pole/wall mount bracket from the azimuth bracket.
4.
Use the socket wrench to evenly tighten all three locknuts (do not over tighten).
NOTE:
During final installation, you loosen these bolts to adjust the azimuth of the module. See
Section, 8.1 “
Using the BSI Feature and Adjusting the Module
” for steps on adjusting the module.
5.
As a final step in module installation, use the torque wrench to evenly tighten down all three
locknuts to finish the installation of the HM or RBM to the pole or wall (do not over tighten). See
Table 11, “Recommended Torque Values for Pole/Wall Mount Bracket Locknuts” for torque values.
Figure 21 Unit Installed onto the Pole/Wall Mount Bracket