Example:
Example:
Example:
Example:
Example:
Example:
31. OBJECT 6300H: SERIAL NUMBER STRING
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
00h
CAN Object 6300h
Byte 2
63h
Byte 3,7
00h
Not used
1° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register second byte
Byte 1, 7
00h
Not used
2° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
70h
Read Device Register third byte
Byte 1, 7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
41 00 63 00 00 00 00 00
Keypad Reply
595
Std
41 00 63 00 06 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad Reply
595
Std
00 30 30 30 30 30 30 00
000000
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad Reply
595
Std
1D 00 00 00 00 00 00 00
Serial number: ascii 000000.
32. OBJECT 6301H: BOOTLOADER PRESENCE
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
01h
CAN Object 6301h
Byte 2
63h
Byte 3,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 01 63 00 00 00 00 00
Keypad Reply
595
Std
4F 01 63 00 00 00 00 00 Bootloader not present
To Keypad
615
Std
40 01 63 00 00 00 00 00
Keypad Reply
595
Std
4F 01 63 00 01 00 00 00 Bootloader present
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - [email protected]
35
FOR REFERENCE ON
LY