PKP3500SI_CANopenUM_REV1.0
30/38
38.
Object 1402h: Receive PDO communication Parm 2
Describes the Receive Parameters for Indicator LED brightness
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
02h
CAN Object 1402h
Byte 2
14h
Byte 3
00h
Highest sub-index supported
01h
COB Id
02h
Transmission Type
Byte 4,7
00h
Not used
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 02 14 00 00 00 00 00
Keypad reply
595
Std
4F 02 14 00 02 00 00 00
2
To Keypad
615
Std
40 02 14 01 00 00 00 00
Keypad reply
595
Std
43 02 14 01 15 04 00 00
0000 0415h
To Keypad
615
Std
40 02 14 02 00 00 00 00
Keypad reply
595
Std
4F 02 14 02 FE 00 00 00
FEh
Receive PDO communication Parm 2:
•
Number of mapped objects: 2;
•
COB id: 0000 0400h + NODE ID;
•
Transmission Type: event-driven.
39.
Object 1403h: Receive PDO communication Parm 3
Describes the Receive Parameters for backlight LED brightness
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
03h
CAN Object 1403h
Byte 2
14h
Byte 3
00h
Highest sub-index supported
01h
COB Id
02h
Transmission Type
Byte 4,7
00h
Not used
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 03 14 00 00 00 00 00
Keypad reply
595
Std
4F 03 14 00 02 00 00 00
2
To Keypad
615
Std
40 03 14 01 00 00 00 00
Keypad reply
595
Std
43 03 14 01 15 05 00 00
0000 0515h
To Keypad
615
Std
40 03 14 02 00 00 00 00
Keypad reply
595
Std
4F 03 14 02 FE 00 00 00
FEh
Receive PDO communication Parm 3:
•
Number of mapped objects: 2;
•
COB id: 0000 0500h + NODE ID;
•