PACKAGE CONTENTS

 

 

BlazeCut T Series Fire Suppression System with a pressure gauge 

 

Cable ties for installation 

 

General warning label ALA008 

 

User manual and information about the substance 

 

BlazeCut logo sticker 

 

FIRE CLASS RATING

 

Extinguishing agent may be used for the following classes of fire (European Classification): 

CLASS A:  

     

 

CLASS C:

 

Ordinary combustibles (creating flames) 

Flammable gases 

CLASS B:

  

            

Energized electrical equipment

 

Flammable liquids 

 

FIRST AID MEASURES

 

 

In case of direct contact with the extinguishing agent, follow the instructions below. 
 

General Information

 

In all cases of doubt, or when symptoms persist, seek medical attention. 
 

Following inhalation: 

 

Move the person to fresh air and keep at rest in a position comfortable for breathing. If the person is not breathing 
or  if  breathing  is  irregular  or  breathing  has  stopped,  administer  artificial  respiration  or  oxygen  by  trained 
personnel. Loosen tight clothing such as collar, tie, waistband, and belt. Do not administer adrenaline  and its 
derivatives. Seek medical

 

attention immediately. 

 

Following skin contact:

 

Flush/irrigate the affected area with large amount of water. Do not use hot water. Remove contaminated clothing 
affected by extinguishing agent. If you experience frostbite, seek

 

medical attention. 

 

Following eye contact:

 

Carefully flush/irrigate with water for several minutes. If possible, remove contact lenses, if they are inserted. 
Continue flushing. Seek medical attention. 
 

Following ingestion:

 

Ingestion is not considered a potential route of exposure. 

 
IMPORTANT! Always ventilate the area after activation.

 

 

CERTIFICATION 

 

The safety and performance of the BlazeCut T Series system was confirmed by various independent bodies. 
Certificates or further information is available from the local BlazeCut agent or at www.blazecut.com. 

 

WARRANTY AND LIFESPAN 

 
BlazeCut  offer  a standard  two-year  warranty  on  all  T  Series models from  the  date  of  a 
retail purchase. A further 3 year conditional extended warranty is offered upon registration. 
For  the  full  terms  and  conditions  of  the  3  year  extended  warranty  and  to  activate  and 
register for the extended warranty please visit www.blazecut.com. A lifespan of up to 10 
years can be achieved in non-harsh environments. Please note that this may reduce in 
unstable and harsh environments. 

Summary of Contents for T Series

Page 1: ...FULLY This user manual contains important information about the BlazeCut T Series fire suppression system its use operation installation and maintenance If further technical information is required please request a copy of the T Series technical manual from a BlazeCut representative ...

Page 2: ...tely Following skin contact Flush irrigate the affected area with large amount of water Do not use hot water Remove contaminated clothing affected by extinguishing agent If you experience frostbite seek medical attention Following eye contact Carefully flush irrigate with water for several minutes If possible remove contact lenses if they are inserted Continue flushing Seek medical attention Follo...

Page 3: ...into one unit The BlazeCut T Series is not compatible with other fire suppression systems do not try to connect the system to any other equipment The system may be installed only by adult persons physically and mentally capable Incorrect interference with the system may cause malfunction of the system and provides threat to safety and health of people The system is under constant pressure any mech...

Page 4: ...18 ft3 0 11 lb 0 07 oz 11 02 in T050E 0 18 m3 0 14 m3 0 10 kg 2 g 53 cm 6 36 ft3 4 94 ft3 0 22 lb 0 07 oz 20 87 in T100E 0 46 m3 0 35 m3 0 25 kg 5 g 113 cm 16 24 ft3 12 36 ft3 0 55 lb 0 17 oz 44 48 in T200E 0 91 m3 0 69 m3 0 50 kg 5 g 215 cm 32 14 ft3 24 37 ft3 1 10 lb 0 17 oz 84 64 in T300E 1 37 m3 1 04 m3 0 75 kg 10 g 319 cm 48 38 ft3 36 73 ft3 1 65 lb 0 35 oz 125 59 in T400E 1 82 m3 1 39 m3 1 0...

Page 5: ...oisonous unnecessary excessive exposure of persons to its influence should be avoided Under no circumstances should persons be exposed to the extinguishing agent for more than 5 minutes also in case when the extinguishing concentration does not exceed the LOAEL level contact your local BlazeCut supplier for more information During the system activation the extinguishing agent is discharged from th...

Page 6: ... with the letter S in model designation have an integrated pressure switch that allows connection of signalling devices or to perform a shutdown operation at agent discharge An IP65 Pressure Switch is factory fitted for outdoor and mobile applications T Series models with the letters S E in model designation have an integrated economy pressure switch that allows connection of signalling devices or...

Page 7: ...ishing effect of the system may be decreased and part or the entire protected enclosure may be damaged 11 Install the system so that it is not exposed to aggressive chemical substances caustic acids solvents corrosive substances etc and avoid direct influence of weather conditions and direct sunlight 12 When fastening the system make sure not to damage other parts of the vehicle or the enclosure 1...

Page 8: ...100 min 1 Maximum pressure 60 bar 870 psi Power rating Angular connector All Current Resistive load AC 12 DC12 AC 250 V DC 24 V 4 A Inductive load AC 14 DC14 AC 250 V DC 24 V 2 A IP rating IP65 with cable connector and seal Electrical outlet DIN EN 175301 803 A Operation temperature from 20 C up to 80 C 4 F to 176 F Tested to EN60947 Low voltage switchgear and control gear IEC 68 2 78 Permissible ...

Page 9: ...er pressure in the tube and vice versa IMPORTANT At very low temperatures the pressure of agent vapours is close to zero Indicator on the pressure gauge can vary from 0 bar 0 psi when temperatures are very low to 17 bar 247 psi when temperatures are very high This is not a sign of defect in the system CASES WHEN THE BLAZECUT SYSTEM MUST BE REPLACED The system is leaking was used or emptied from ot...

Page 10: ... waste NEED SOMETHING MORE If there is a requirement for electronic monitoring external alarm or other size of system these are available Please contact technical blazecutgroup com GLOBAL HEAD OFFICE BlazeCut Pty Ltd 45 Evans St Balmain NSW 2041 Australia Tel 61 2 8006 1300 MANUFACTURER BlazeCut s r o Priemyselná 2521 90027 Bernolákovo Slovakia www blazecut com technical blazecutgroup com BlazeCut...

Reviews: