PAGE 16
OM-9703
Date Printed: Thursday, July 05, 2007
Revision Date: March 6, 2006
The gas line may be installed at this time.
Make sure to follow all provincial and local codes. Blaze King
recommends that gas connections be made by a Licensed and qualified installer.
The appliance can be
connected to the supply line with either rigid or approved flexible gas connection. Check with provincial and local
codes.
PIPING DETAIL:
NOTE:
DO NOT DAMAGE OR KINK THE FLEX CONNECTOR. CHECK FOR GAS LEAKS WITH SOAP AND
WATER SOLUTION.
1/2 INCH FLEX OR RIGID PIPING MAY BE USED TO CONNECT THE GAS SUPPLY TO THE UNIT
DEPENDING ON STATE, PROVINCIAL AND LOCAL CODES.
GAS SUPPLY PRESSURE:
NATURAL GAS............................7 inch w.c. recommended 5.5 min / 10.5 max
1/2” Flex connector or rigid pipe.
GAS CONNECTION
9703 - FREE STANDING
30”
9703 - FREESTANDING & INSERT CLEARANCE DIAGRAMS
9703 - FREE STANDING
18”
5-1/4”
8”
20”
Min. to
combustibles
Min. to
combustibles
Gas supply
Supply line
1/2” Gas shut off valve open position
30”
10”
Min. to
combustibles
9703 - FREE STANDING
2” MINIMUM TO
COMBUSTIBLES
2”
M
IN
IM
U
M
TO
C
O
M
B
U
ST
IB
LE
S
Gas supply
12-1/2”
9703 - INSERT
16”
12-3/4”
9”
Min. to
combustibles
11”