MAINTENANCE
Regularly,
- Clean and remove any lint accumulations or debris from the grills and in any combustion and convection
air passage ways.
- Keep the appliance area free from combustible materials, such as paper, wood, clothing, gasoline and
flammable solids, liquids and vapors.
- Check for unusual noise, odor and operation of the appliance.
- Check the vent terminal for any damage, or obstruction by plants or debris accumulation.
- Visually check the height and color of the burner and pilot flames.
Once a Year,
- Remove the glass door and clean the inside of the glass with a soft,
non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner.
- Carefully remove the logs and gently brush off any loose carbon
deposits. This job is best done outside the house, wearing a dust
mask.The logs are very fragile, take care not to break them. After
cleaning, the logs must be replaced as per the instructions in this
manual.
Once a Year have a qualified service technician,
- Completely inspect the appliance and the venting system.
- Clean and remove any lint accumulations or debris in the firebox, on the burners, on the pilot,
at the primary air opening, on the convection air blower and in any combustion and convection
air passage ways.
- Check the safety shut-off system of the gas valve.
WARNING :
All parts removed or disturbed must be properly replaced after maintenance.
Service and repair must be conducted by a qualified service person. If these
instructions are not followed, a fire or explosion may result, causing property
damage, personal injury or loss of life.
VERIFY PROPER OPERATION AFTER SERVICING.
CLEANING THE APPLIANCE
The exterior surfaces and glass may be cleaned with a soft, non-abrasive cloth and water or a suitable,
mild, non-abrasive cleaner.
INTERMITTENT PILOT FLAME:
MAIN FLAME
Figure 12
Figure 14
CAUTION :
Do not conduct maintenance on the appliance while it is operating or while it is still hot.
Make sure Remote switch on the Module is in OFF position (See figure 9 page 29) and turn
burner switch OFF. Turning the electric supply off will not prevent unexpected ignition !!
Summary of Contents for CALDERA
Page 6: ...THE CALDERA Page 6 APPLIANCE DIMENSIONS Figure 1 ...
Page 33: ...THE CALDERA Page 33 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 34: ...THE CALDERA Page 34 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 35: ...THE CALDERA Page 35 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Page 43: ...THE CALDERA Page 43 FUEL CONVERSION ...
Page 49: ...THE CALDERA Page 49 FAN KIT INSTALLATION continued Figure 24 ...
Page 51: ...THE CALDERA Page 51 Replacement Parts list for Caldera 1 ...
Page 53: ...THE CALDERA Page 53 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...