- 2 -
D
Inhaltsverzeichnis
Inhaltsverzeichnis, Ausstattung des Arbeitsplatzes ...................... 2
Meßpunkte .................................................................................... 3
Main Feature list Funline3 ............................................................ 4
Main Feature list T-Line2 .............................................................. 5
Belegung des Anschlußkastens ................................................... 6
Vorbereitende Arbeiten, Abgleichhinweise
Reparaturhinweise, Demomode ................................................... 7
Antennenanpassung ..................................................................... 8
MAUS - So Hardware .............................................. 9 + 10
F3/T2_ASB_EU CFG Datei installieren ............................... 11 - 13
Comport setzen .......................................................................... 14
Konfigurationsdatei laden ................................................... 15 + 16
EEPROM programmieren ................................................... 17 + 18
DAA programmieren ........................................................... 19 + 20
Programmierung der FM - ZF - Ablage ....................................... 21
FM Feldstärke programmieren ................................................... 22
AM Feldstärke programmieren ................................................... 23
Programmieren der Stereo Schaltschwelle ................................. 24
FM Suchlaufstop - Programmierungen ....................................... 25
AM/MW Suchlaufstop - Programmierungen ................................ 26
AM/LW Suchlaufstop - Programmierungen ................................. 27
Programmieren der RDS Schaltschwelle .................................... 28
Dolby - Abgleich .......................................................................... 29
Ausstattung des Arbeitsplatzes:
1.
PC ab Pentium
II
oder höher
2.
"ComServer" So Donglet Lies mich Datei
8 627 003 058 (1 CD-Rom Win95/98 + WinNT)
3.
Interface (MAUS-Bus / K-Bus auf RS232 Schnittstelle)
8 627 004 057
4.
Steckernetzteil für Interface (12V / 500mA) 8 627 004 061
5.
Dongle (Hardware Sicherheitssystem in Verbindung mit dem
MAUS-Bus) 8 627 004 059 (nur für dekodierberechtigte
Servicestellen)
6.
Anschlußkabel MAUS-Bus (Lautsprecher-ISO Stecker mit 2
Kontaktnadeln) 8 627 004 042
7.
Verbindungskabel RS232 (PC zum Interface) 8 627 004 015
8.
Konfigurationsdateien (MAUS-Bus-Kom Servicean-
leitung MAUS) für die F3/T2 Geräte mit der Bestellnummer
8 627 003 072 (1 Diskette MS DOS 3
1
/
2
Zoll)
9.
Netzgerät 15 V regelbar, 10 A
(Betriebsspannung service 13,5 V)
10. Meßsender (z.B. Meguro, Leader, Kenwood)
11. Hochohmiges Voltmeter Ri > 10 M
Ω
12. Outputmeter; Frequenzzähler; NF-Millivoltmeter; Stereocoder
13. Oszilloskop:
- Empfindlichkeit: 5 mV bis 50 Volt/cm.
- Bandbreite: Gleichspannung bis 50 MHz.
14. Tastköpfe 10:1 und 1:1
15. Schraubendreher / Abgleichstifte (keramisch)
16. Lötstation
Die Ausstattungselemente von Punkt 2 bis 8 können über
unser zentrales Ersatzteillager bestellt werden.
Voraussetzung dafür ist, dass ein entsprechender Service- und
Softwarevertrag mit Blaupunkt abgeschlossen wurde.
Haben Sie dazu Fragen, wenden Sie sich bitte an Ihren
nationalen Servicemanager.
Adresse:
Blaupunkt-Werke GmbH
Zentrales Ersatzteillager
Robert-Bosch-Straße 200
D-31139 Hildesheim
GB
Table of Contents
Table of Contents, Work place equipment .................................... 2
Measuremend points .................................................................... 3
Main Feature list Funline3 ............................................................ 4
Main Feature list T-Line2 .............................................................. 5
Pinning of terminal box ................................................................. 6
Preparatory steps, Notes on alignment ......................................... 6
Repair notes, demo mode ............................................................ 7
Antenna matching ......................................................................... 8
MAUS so hardware .......................................................... 9
Installation of F3/T2_ASB_EU CFG file .............................. 11 - 13
Setting the comport ..................................................................... 14
Loading the configuration file .............................................. 15 + 16
Programming the EEPROM ............................................... 17 + 18
Programming DAA .............................................................. 19 + 20
Programming of FM IF offset ...................................................... 21
Programming of the FM fieldstrengh ........................................... 22
Programming of the AM fieldstrengh ........................................... 23
Programming of the stereo threshold .......................................... 24
FM search stop programming ..................................................... 25
AM/MW search stop programming ............................................. 26
AM/LW search stop programming .............................................. 27
Programming of the RDS threshold ............................................ 28
Dolby alignment .......................................................................... 29
Work place equipment:
1.
Pentium
II
or higher
2.
"ComServer" so dongle read-me files
8 627 003 058 (1 CD-Rom Win 95/98 + WinNT)
3.
Interface (MAUS bus / K-bus to RS232 interface)
8 627 004 057
4.
Power adapter for interface (12V / 500mA) 8 627 004 061
5.
Dongle (hardware security system in connection with the MAUS
bus) 8 627 004 059 (for authorised decoding agents only)
6.
MAUS bus cable (ISO speaker connector with 2 pins)
8 627 004 042
7.
Extension cable RS232 (PC to interface) 8 627 004 015
8.
Configuration files (MAUS bus co service manual
MAUS) for the F3/T2 units with order number 8 627 003 072
(1 MS DOS 3
1
/
2
inch diskette).
9.
Power supply unit 15 volts adjustable, 10 A
(Supply voltage service 13.5 V)
10. Signal generator (Meguro, Leader, Kenwood)
11. High impedance voltmeter Ri > 10 M
Ω
12. Output meter; frequency counter; AF millivoltmeter; stereo
encoder
13. Oscilloscope: - inp. sensitivity: 5 mV to 50 volts per division
- bandwidth: d.c. to 50 MHz
14. Probes 10:1 and 1:1
15. Screwdriver / adjusting pins (ceramic)
16. Soldering station
The items listed under 2 - 8 are available from our Central
Spare Parts Warehouse.
For this it is necessary that you have entered into a
corresponding service and software agreement with Blau-
punkt. If you should have any questions on this topic, then
please get in touch with your national service manager.
Adress:
Blaupunkt-Werke GmbH
Zentrales Ersatzteillager
Robert-Bosch-Straße 200
D-31139 Hildesheim