background image

MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby 
declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/
EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance 
of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation 
through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the 
manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults 
in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means 
of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include: 

•  routine technical maintenance
•  unit installation/dismantling 
•  unit setup
To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment 
paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty 
service. 

The manufacturer’s warranty does not apply to the following cases:

•  User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing 

component parts previously dismounted by the user.

•  Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.
•  User’s failure to ensure timely technical maintenance of the unit.
•  External damage to the unit casing (excluding external modifications as required for installation) and internal components caused 

by the user.

•  Redesign or engineering changes to the unit.
•  Replacement and use of any assemblies, parts and components not approved by the manufacturer.
•  Unit misuse.
•  Violation of the unit installation regulations by the user.
•  Violation of the unit control regulations by the user.
•  Unit connection to power mains with a voltage different from the one stated in the user's manual.
•  Unit breakdown due to voltage surges in power mains.
•  Discretionary repair of the unit by the user.
•  Unit repair by any persons without the manufacturer’s authorization.
•  Expiration of the unit warranty period.
•  Violation of the unit transportation regulations by the user.
•  Violation of the unit storage regulations by the user.
•  Wrongful actions against the unit committed by third parties.
•  Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
•  Missing seals if provided by the user’s manual.
•  Failure to submit the user’s manual with the unit purchase date stamp.
•  Missing payment paperwork certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND 

TROUBLE-FREE OPERATION OF THE UNIT.

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON 

PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL 

WITH THE PURCHASE DATE STAMP.

www.blaubergventilatoren.de

BlauAir CFh

13

Summary of Contents for BlauAir BL02 CFH 1500

Page 1: ...Air handling unit BlauAir CFH USER S MANUAL EN ...

Page 2: ...ling and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information Failure to follow the rules a...

Page 3: ...on and maintenance operations with wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits sm...

Page 4: ...environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs The unit has C4 corrosion resistance class in compliance with ISO 12944 DELIVERY SET Name Number Unit 1 pc User s manual 1 pc Technical data sheet 1 pc Automation wiring 1 pc Control panel 1 pc User s manual for automation 1 pc Packing box 1 pc DESIGNATION KEY BlauAir BL02 CF H 2500 HW CDX L S3...

Page 5: ...age and connected pipelines must be provided during sub zero ambient temperatures if the unit is equipped with an air cooler The heat medium temperature in the water heat exchangers if available must be sufficient to prevent its freezing Hazardous parts access and water ingress protection rating IP54 for the unit motors IP42 for the assembled unit connected to the air ducts without extra cover or ...

Page 6: ...0 HW 2410 3 4 BL03 CFH 3500 1390 1003 350 2370 930 600 358 440 BL03 CFH 3500 HE BL03 CFH 3500 HW 2730 3 4 BL07 CFH 5000 BL07 CFH 6000 1520 1218 500 2500 1430 100 479 690 BL07 CFH 5000 HE BL07 CFH 6000 HE BL07 CFH 5000 HW BL07 CFH 6000 HW 2830 1 The full technical data list is stated in the supplied technical data sheet BlauAir CFH 6 www blaubergventilatoren de ...

Page 7: ... units with water heater 3 electric heater only for the models with electric heater 4 supply fan 5 water heater only for the units with water heater 6 extract filter 7 heat exchanger 8 extract fan 9 air flow control damper with electric actuator 10 bypass damper 11 supply filter 12 control unit www blaubergventilatoren de BlauAir CFH 7 ...

Page 8: ...aust air duct During installation works sufficient maintenance and service access must be provided The recommended minimum distances from the unit to the walls are shown below 200 A Casing dimensions A mm BL02 CFH BL03 CFH 600 BL07 CFH 800 The delivery set includes removable levelling feet to adjust horizontal levelling of the unit and provide required clearance from the floor to enable correct mo...

Page 9: ... 2600 340 170 Connect the drain pipe U trap and sewage system using metal plastic or rubber connecting pipes min 3 3 2 1 2 4 1 drain pipe 2 connecting pipe 3 U trap 4 sewage system Prior to starting operation make sure that water has unobstructed flow in the sewage system Fill the U trap with water before operation Connection of the water heater only for the models with water heater While connecti...

Page 10: ...ric heater may lead to unpleasant odours It is not a malfunction Clean the unit to troubleshoot unpleasant odours Open the service doors to access the filters Remove the two butterfly bolts that fix the retaining clamp Remove the filter elements CONNECTION TO POWER MAINS Connection to power mains must be conducted in compliance with the automation user s manual TECHNICAL MAINTENANCE OPEN THE UNIT ...

Page 11: ...To access the heat exchanger remove the service panel Loosen the screws 1 on the retaining clamps 2 using a hexagon wrench 1 1 2 Pull the heat exchanger out www blaubergventilatoren de BlauAir CFH 11 ...

Page 12: ...ions to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit can be transported only in the working position Avoid sharp blows scratches or rough handling during loading and unloading P...

Page 13: ...ser s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casi...

Page 14: ...BlauAir CFH 14 www blaubergventilatoren de ...

Page 15: ...ged and accepted Customer s Signature The BlauAir BL___CFH__________ unit has been connected to power mains pursuant to the requirements stated in the present user s manual Installation Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction ...

Page 16: ...www blaubergventilatoren de B192 3EN 01 ...

Reviews: