PURPOSE 

THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED 

PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT 

THE APPROPRIATE TRAINING. 

THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED 

PERSONNEL AFTER THE APPROPRIATE BRIEFING.

THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED 

ACCESS BY UNATTENDED CHILDREN.

The air handling unit with heat recovery is designed for integration into central mechanical ventilation systems. 
The unit is rated for continuous operation.
Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, 
coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, 
pathogenic germs).
The unit has C4 corrosion resistance class in compliance with ISO 12944.

DELIVERY SET 

Name 

Number 

Unit 

1 pc.

User's manual 

1 pc.

Technical data sheet 

1 pc.

Automation wiring 

1 pc.

Control panel 

1 pc.

User's manual for automation 

1 pc.

Packing box 

1 pc.

DESIGNATION KEY 

BlauAir

BL02

CF

H

2500

HW

CDX

L

S30

Automation type 

S30 : kVent with thTune control panel 
S31: kVent 
S32: kVent  with pGDE control panel 

Service modification 

L: left-sided modification 
R: right-sided modification 

Cooler type 

_: no cooler 
CDX: DX-cooler 
CW: water cooler 

Heater type

_: no heater 
HE: electric heater
HW: water heater 

Air capacity [m

3

/h]

Unit installation modification 

P: suspended 
H: double-deck 
V: vertical 

Heat exchanger type 

R: rotary 
CF: counter-flow 

Casing dimensions 
Unit series 

BlauAir CFh

4

www.blaubergventilatoren.de

Summary of Contents for BlauAir BL02 CFH 1500

Page 1: ...Air handling unit BlauAir CFH USER S MANUAL EN ...

Page 2: ...ling and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information Failure to follow the rules a...

Page 3: ...on and maintenance operations with wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits sm...

Page 4: ...environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs The unit has C4 corrosion resistance class in compliance with ISO 12944 DELIVERY SET Name Number Unit 1 pc User s manual 1 pc Technical data sheet 1 pc Automation wiring 1 pc Control panel 1 pc User s manual for automation 1 pc Packing box 1 pc DESIGNATION KEY BlauAir BL02 CF H 2500 HW CDX L S3...

Page 5: ...age and connected pipelines must be provided during sub zero ambient temperatures if the unit is equipped with an air cooler The heat medium temperature in the water heat exchangers if available must be sufficient to prevent its freezing Hazardous parts access and water ingress protection rating IP54 for the unit motors IP42 for the assembled unit connected to the air ducts without extra cover or ...

Page 6: ...0 HW 2410 3 4 BL03 CFH 3500 1390 1003 350 2370 930 600 358 440 BL03 CFH 3500 HE BL03 CFH 3500 HW 2730 3 4 BL07 CFH 5000 BL07 CFH 6000 1520 1218 500 2500 1430 100 479 690 BL07 CFH 5000 HE BL07 CFH 6000 HE BL07 CFH 5000 HW BL07 CFH 6000 HW 2830 1 The full technical data list is stated in the supplied technical data sheet BlauAir CFH 6 www blaubergventilatoren de ...

Page 7: ... units with water heater 3 electric heater only for the models with electric heater 4 supply fan 5 water heater only for the units with water heater 6 extract filter 7 heat exchanger 8 extract fan 9 air flow control damper with electric actuator 10 bypass damper 11 supply filter 12 control unit www blaubergventilatoren de BlauAir CFH 7 ...

Page 8: ...aust air duct During installation works sufficient maintenance and service access must be provided The recommended minimum distances from the unit to the walls are shown below 200 A Casing dimensions A mm BL02 CFH BL03 CFH 600 BL07 CFH 800 The delivery set includes removable levelling feet to adjust horizontal levelling of the unit and provide required clearance from the floor to enable correct mo...

Page 9: ... 2600 340 170 Connect the drain pipe U trap and sewage system using metal plastic or rubber connecting pipes min 3 3 2 1 2 4 1 drain pipe 2 connecting pipe 3 U trap 4 sewage system Prior to starting operation make sure that water has unobstructed flow in the sewage system Fill the U trap with water before operation Connection of the water heater only for the models with water heater While connecti...

Page 10: ...ric heater may lead to unpleasant odours It is not a malfunction Clean the unit to troubleshoot unpleasant odours Open the service doors to access the filters Remove the two butterfly bolts that fix the retaining clamp Remove the filter elements CONNECTION TO POWER MAINS Connection to power mains must be conducted in compliance with the automation user s manual TECHNICAL MAINTENANCE OPEN THE UNIT ...

Page 11: ...To access the heat exchanger remove the service panel Loosen the screws 1 on the retaining clamps 2 using a hexagon wrench 1 1 2 Pull the heat exchanger out www blaubergventilatoren de BlauAir CFH 11 ...

Page 12: ...ions to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit can be transported only in the working position Avoid sharp blows scratches or rough handling during loading and unloading P...

Page 13: ...ser s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casi...

Page 14: ...BlauAir CFH 14 www blaubergventilatoren de ...

Page 15: ...ged and accepted Customer s Signature The BlauAir BL___CFH__________ unit has been connected to power mains pursuant to the requirements stated in the present user s manual Installation Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction ...

Page 16: ...www blaubergventilatoren de B192 3EN 01 ...

Reviews: