CONTENTS

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the BlauAir CFH unit 
and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
perform works in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the 
country.
The information in this user’s manual is correct at the time of the document’s preparation.  
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to 
incorporate the latest technological developments.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information 
search system or translated into any language in any form without the prior written permission of the Company.

SAFETY REQUIREMENTS

•  Please read the user’s manual carefully prior to installing and operating the unit.
•  All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical 

norms and standards must be observed when installing and operating the unit.

•  The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
•  Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
•  After a careful reading of the manual, keep it for the entire service life of the unit.
•  While transferring the unit control, the user’s manual must be turned over to the receiving operator.

Safety requirements ..................................................................................................................................................................... 2
Purpose  ............................................................................................................................................................................................... 4
Delivery set  ....................................................................................................................................................................................... 4
Designation key  ............................................................................................................................................................................ 4
Technical data .................................................................................................................................................................................. 5
Unit design and operation logic .......................................................................................................................................... 7
Installation and set-up  .............................................................................................................................................................. 8
Connection to power mains  ................................................................................................................................................. 10
Technical maintenance  ............................................................................................................................................................ 10
Storage and transportation regulations .......................................................................................................................... 12
Manufacturer’s warranty ........................................................................................................................................................... 13
Certificate of acceptance .......................................................................................................................................................... 15
Seller information  ......................................................................................................................................................................... 15
Installation certificate .................................................................................................................................................................. 15
Warranty card ................................................................................................................................................................................... 15

UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS

•  Disconnect the unit from power mains prior 

to any installation operations.

•  Unpack the unit with care.

•  The unit must be grounded!

•  While installing the unit, follow the safety 

regulations specific to the use of electric 
tools.

BlauAir CFh

2

www.blaubergventilatoren.de

Summary of Contents for BlauAir BL02 CFH 1500

Page 1: ...Air handling unit BlauAir CFH USER S MANUAL EN ...

Page 2: ...ling and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information Failure to follow the rules a...

Page 3: ...on and maintenance operations with wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits sm...

Page 4: ...environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs The unit has C4 corrosion resistance class in compliance with ISO 12944 DELIVERY SET Name Number Unit 1 pc User s manual 1 pc Technical data sheet 1 pc Automation wiring 1 pc Control panel 1 pc User s manual for automation 1 pc Packing box 1 pc DESIGNATION KEY BlauAir BL02 CF H 2500 HW CDX L S3...

Page 5: ...age and connected pipelines must be provided during sub zero ambient temperatures if the unit is equipped with an air cooler The heat medium temperature in the water heat exchangers if available must be sufficient to prevent its freezing Hazardous parts access and water ingress protection rating IP54 for the unit motors IP42 for the assembled unit connected to the air ducts without extra cover or ...

Page 6: ...0 HW 2410 3 4 BL03 CFH 3500 1390 1003 350 2370 930 600 358 440 BL03 CFH 3500 HE BL03 CFH 3500 HW 2730 3 4 BL07 CFH 5000 BL07 CFH 6000 1520 1218 500 2500 1430 100 479 690 BL07 CFH 5000 HE BL07 CFH 6000 HE BL07 CFH 5000 HW BL07 CFH 6000 HW 2830 1 The full technical data list is stated in the supplied technical data sheet BlauAir CFH 6 www blaubergventilatoren de ...

Page 7: ... units with water heater 3 electric heater only for the models with electric heater 4 supply fan 5 water heater only for the units with water heater 6 extract filter 7 heat exchanger 8 extract fan 9 air flow control damper with electric actuator 10 bypass damper 11 supply filter 12 control unit www blaubergventilatoren de BlauAir CFH 7 ...

Page 8: ...aust air duct During installation works sufficient maintenance and service access must be provided The recommended minimum distances from the unit to the walls are shown below 200 A Casing dimensions A mm BL02 CFH BL03 CFH 600 BL07 CFH 800 The delivery set includes removable levelling feet to adjust horizontal levelling of the unit and provide required clearance from the floor to enable correct mo...

Page 9: ... 2600 340 170 Connect the drain pipe U trap and sewage system using metal plastic or rubber connecting pipes min 3 3 2 1 2 4 1 drain pipe 2 connecting pipe 3 U trap 4 sewage system Prior to starting operation make sure that water has unobstructed flow in the sewage system Fill the U trap with water before operation Connection of the water heater only for the models with water heater While connecti...

Page 10: ...ric heater may lead to unpleasant odours It is not a malfunction Clean the unit to troubleshoot unpleasant odours Open the service doors to access the filters Remove the two butterfly bolts that fix the retaining clamp Remove the filter elements CONNECTION TO POWER MAINS Connection to power mains must be conducted in compliance with the automation user s manual TECHNICAL MAINTENANCE OPEN THE UNIT ...

Page 11: ...To access the heat exchanger remove the service panel Loosen the screws 1 on the retaining clamps 2 using a hexagon wrench 1 1 2 Pull the heat exchanger out www blaubergventilatoren de BlauAir CFH 11 ...

Page 12: ...ions to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit can be transported only in the working position Avoid sharp blows scratches or rough handling during loading and unloading P...

Page 13: ...ser s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casi...

Page 14: ...BlauAir CFH 14 www blaubergventilatoren de ...

Page 15: ...ged and accepted Customer s Signature The BlauAir BL___CFH__________ unit has been connected to power mains pursuant to the requirements stated in the present user s manual Installation Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction ...

Page 16: ...www blaubergventilatoren de B192 3EN 01 ...

Reviews: