vento eco

2

CONTENTS

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the VENTO Eco unit and 
all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery set ........................................................................................................................................................................................ 4
Designation key .............................................................................................................................................................................. 4
Technical data .................................................................................................................................................................................. 5
Design and operating principle ........................................................................................................................................... 6
Mounting and set-up .................................................................................................................................................................. 8
Connection to power mains .................................................................................................................................................. 11
Technical maintenance .............................................................................................................................................................. 16
Troubleshooting ............................................................................................................................................................................. 17
Storage and transportation regulations .......................................................................................................................... 17
Manufacturer’s warranty ........................................................................................................................................................... 18
Certificate of acceptance .......................................................................................................................................................... 19
Seller information .......................................................................................................................................................................... 19
Installation certificate .................................................................................................................................................................. 19
Warranty card ................................................................................................................................................................................... 19

All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing 
and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are 

allowed for installation. The present user’s manual should be carefully read before 

beginning works.

Check the unit for any visible damage of the impeller, the casing, and the grille before starting 
installation. The casing internals must be free of any foreign objects that can damage the 
impeller blades. 
While mounting the unit, avoid compression of the casing! Deformation of the casing may result 
in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the device to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 
materials.
Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, 
insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the efficient air flow.
Do not sit on the unit and do not put objects on it.

SAFETY REQUIREMENTS

Summary of Contents for VENTO Eco A50-4 Pro1

Page 1: ...Heat regeneration single room reversible ventilator USER S MANUAL EN VENTO Eco A50 4 Pro1 VENTO Eco2 A50 4 Pro1...

Page 2: ...construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenan...

Page 3: ...owledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play wi...

Page 4: ...rille type 4 white internal grille with a smooth panel Rated air capacity m3 h Air duct cross section A round Ventilator series VENTO Eco series with one ventilator and one control panel VENTO Eco2 se...

Page 5: ...IP24 The unit design is constantly being improved thus some models may be slightly different from those described in this manual A 160 Air duct length wall thickness Outer ventilation hood Indoor unit...

Page 6: ...l to prevent ingress of water and foreign objects into the ventilator Front part of the indoor unit Fulfils the decorative function It is a part of the indoor unit design and directs the air flow upwa...

Page 7: ...from the room As it flows through the regenerator it heats and moisturizes the regenerator transferring heat and air moisture 70 seconds after the ceramic regenerator starts to get warmed the ventila...

Page 8: ...ide Do not disconnect the connectors on the circuit boards in the casing 3 Connect the wires to the terminal blocks on the back side of the control panel in compliance with external wiring diagrams Fi...

Page 9: ...ecommended to make preparations for layout of the power cable and other required cables in the wall The hole size and minimum distance to the surface e g wall ceiling or window and the minimum distanc...

Page 10: ...rk the point 1 on the sound absorbing mat on the level of the air duct edge Cut out the excessive part of the sound absorbing mat Insert the adjusted sound absorbing roll in the air duct Do not use an...

Page 11: ...the following criteria Always use shielded cables Wire cross section depends on the length and is selected according to the table below Cable length m Minimum wire cross section in the cable mm2 5 0 2...

Page 12: ...n operation mode timer based ventilator operation 4 hours at the high speed or 8 hours at the low speed The display shows the parameters current speed current operation mode timer operating status ON...

Page 13: ...w speed middle speed high speed timer Parameter setting using the or buttons 4 hours at the high speed 8 hours at the low speed turning timer off The ventilator reverts to operation with a previous sp...

Page 14: ...ventilator will run at the permanent low speed speed setting Parameter setting using the or buttons Set the value 5 6 Return to user menu Press several times the button till the main window of the us...

Page 15: ...Ventilation mode The ventilator runs exclusively in the supply or extract mode In case of installation of two ventilators the air flow direction depends on the external wiring refer the wiring diagra...

Page 16: ...wn 90 days the control panel displays the filter replacement indicator Wash the filters and let those dry out completely Install the dry filters in the air duct Vacuum cleaning is allowed To reset the...

Page 17: ...ing temperature for at least 3 4 hours TROUBLES ANDTROUBLESHOOTING Trouble Possible reasons Troubleshooting The fan does not move up during start up of the unit The control panel displays no informati...

Page 18: ...ismantling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model mus...

Page 19: ...ION CERTIFICATE The VENTO Eco ____________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technici...

Page 20: ...www blaubergventilatoren de B127 1EN 01...

Reviews: