background image

www.blaubergventilatoren.de

3

Iso-K

BLAUBERG Ventilatoren GmbH Company is happy to offer your attention 

the sound-insulated fan 

BLAUBERG Iso-K

.

INTRODUCTION

The present operation manual contains technical description, technical 

data sheets, operation and mounting guidelines, safety precautions and 

warnings for safe and correct operation of the fan. 

GENERAL

The sound-insulated Iso-K fans are designed for hot and highly polluted 

air extraction with the temperature up to 100 °C in high resistance condition.

The fans are used as a component of ventilation systems installed in:

- industrial kitchens;

- industrial bakeries;

- metal processing workshops (post-welding gas removal).

The fan is available for round air ducts Ø 150, 160, 200 and 315 mm. 

The fan must be grounded. 

The fan is allowed for operation only after final mounting, that includes 

installation of protecting devices in compliance with DIN EN ISO 13875 (DIN 

EN ISO 12100) as well as other construction safety equipment.

The fan design is regularly improved, so some models can slightly differ 

from those ones described in this operation manual.

SAFETY RULES

The fan complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

All operations related to the electrical connection of the fan, like servicing 

and repair works are allowed only after the disconnection from power mains.

All mounting and servicing operations are allowed for duly qualified 

electricians with valid electrical work permit for electric operations at the 

units up to 1000 V after careful study of the present operation manual. 

Please follow the safety regulations and working instructions (DIN EN 50 

110, IEC 364).

Make sure the impeller and the casing are not damaged before 

connecting the fan to power mains. The casing internals must be free of any 

foreign objects which can damage the impeller blades.

Disconnect the fan from power mains prior to any operations related to 

the servicing and repair works. Make sure the rotating parts have come to a 

full stop. 

Take measures to prevent contact with the fan to avoid physical damages 

during the fan test and start-up. 

Misuse of the product or any unauthorized modification are not allowed. 

The fan is designed for connection to ac single-phase or ac three-phase 

power mains, see "Technical Data". The fan is rated for permanent operation 

during non-stop power supply. 

Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney flues or other 

fire-protection devices. Sufficient air supply must be provided for proper 

combustion and exhaust of gases through the chimney of fuel burning 

equipment to prevent back drafting.  The maximum permitted pressure 

difference per living units is 4 Pa.

The transported air must not contain any dust or other solid impurities, 

sticky substances or fibrous materials. 

The fan is not designed for use in an inflammable and explosive medium. 

The transported medium must not have an aggressive effect on steel at 

the temperature stated in the table 1 of the section “Technical data”. 

The fan motor has F class winding insulation and IP 54 ingress protection 

rating.

Do not close or block the intake or exhaust vent not to disturb the normal  

air circulation. 

Do not sit on the fan and do not put objects on the fan.

Follow the manual guidelines to ensure trouble-free operation and long 

service life of the product.

STORAGE AND TRANSPORTATION RULES

Store the delivered fan in the manufacturer's original packing box in a dry 

ventilated premise with the ambient temperature  from  +5°C up to + 40°C.

Store the fan in an environment with minimized risk of mechanical 

damages, temperature and humidity fluctuations. Store the fan inside a room 

or under a shelter.  

Transportation of the fan is allowed by any vehicle provided the fan is 

transported in the original package and is protected against weather and 

mechanical damages. 

Use hoist machinery for handling and transportation to prevent possible 

mechanical damages. 

Fulfil the requirements for transportation of the specified cargo type 

during cargo-handling operations. 

Do not expose the fan to extremely low or high temperatures.

MANUFACTURER'S WARRANTY 

The fan complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

The manufacturer hereby warrants normal operation of the fan over the 

period of two years from the retail sale date provided observance of the 

installation and operation regulations.

In case of failure due to faulty equipment during the warranty period the 

consumer has the right to exchange it.

If case of no confirmation of the sale date, the warranty term shall be 

calculated from the manufacturing date.

The replacement is offered by the Seller. 

The MANUFACTURER shall not be liable for any damage resulting from 

any misuse of or gross mechanic interference with the fan.

Fulfil the operation manual requirements to ensure a trouble-free and 

long service life of the fan.

 

                WARNING

Do not dispose in domestic waste. The product 

contains in part material that can be recycled and in 

part substances that should not end up as domestic 

waste. Dispose of the fan once it has reached the end of 

its working life according to the regulations valid where 

you are.

The product is not allowed for use by children and persons with 

reduced physical, mental or sensory capacities, without proper practical 

experience or expertise, unless they are controlled or instructed on the 

product operation by the person(s) responsible for their safety. 

Supervise the children and do not let them play with the product. 

!

WARNING

Iso-K_v.1(2)-EN.indd   3

10.08.2015   15:21:00

Summary of Contents for Iso-K 150 4D

Page 1: ...OPERATION MANUAL Iso K SOUND INSULATED FAN Iso K_v 1 2 EN indd 1 10 08 2015 15 20 59...

Page 2: ...ts 3 Manufacturer s warranty 3 Fan design 4 Delivery set 4 Technical data 5 Mounting and operation guidelines 6 Mounting sequence 6 Connection to power mains 7 Maintenance 8 Troubleshooting 8 Acceptan...

Page 3: ...ference per living units is 4 Pa The transported air must not contain any dust or other solid impurities sticky substances or fibrous materials The fan is not designed for use in an inflammable and ex...

Page 4: ...le or three speed motor with short circuit rotor and a centrifugal impeller with forward curved blades The impeller is made of galvanized steel The motor is equipped with ball bearings for longer serv...

Page 5: ...0 100 20 100 20 100 20 100 20 100 Ingress Protection Rating IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 Table 2 Overall dimensions D L3 L4 H1 L L1 B D L4 H1 B1 L2 H D Type Dimensions mm Weight kg D B B1 H H1...

Page 6: ...ectors the fan must be secured to a mounting surface with supports hanger brackets or brackets The air motion direction in the system must match the pointer on the fan casing Install the fan to ensure...

Page 7: ...lectrical parameters of the fan are stated on the rating plate No modifications of internal connections are allowed and will result in void warranty Connect the fan only to power mains with valid elec...

Page 8: ...everse QF ATTENTION Cut power supply to the fan off by turning the automatic electric switch QF to OFF position Take steps to prevent activation of the automatic switch prior to finishing maintenance...

Page 9: ...arking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the produ...

Page 10: ..._____ _______________________________________________________________________________________ _______________________________________________________________________________________ __________________...

Page 11: ..._____ _______________________________________________________________________________________ _______________________________________________________________________________________ __________________...

Page 12: ...www blaubergventilatoren de Iso K v 1 2 EN Iso K_v 1 2 EN indd 12 10 08 2015 15 21 03...

Reviews: