Freshbox (E)/(E1)/(E2)-200 ErV WiFi

19

Basic settings

 

Timers

Main timer: timer mode settings. 
When the timer is activated in the Home page menu, the unit temporarily goes to the following settings:

 

1

  Selection of pre-set speed 1-5, Standby..

00:30

   Timer setting

 

 

Control temperature selection. Ava15 °С.. + 30 °С, off. If OFF is selected, temperature 

control will not be performed while the timer is running.

Boost turn-off delay: 

determines the turn-off delay time for the Boost mode after the signal at the 

digital input (Boost switch) disappears on the control board.

Boost turn-on delay:

 determines the turn-on delay time for the Boost mode after the signal is applied 

to the digital input (Boost switch).

Schedule

The weekly schedule can be set by means of 4 time intervals available for each day of the week. 
Adjustment can be made for every day, weekdays, weekends or for the whole week. 
When the Schedule mode is activated from the 

Main page

, the unit will operate as scheduled 

according to the following parameters:

 

1

  Selection of pre-set speed 1-5, Standby.

 Time setting for a specific segment.

 

 

Control temperature selection. Ava15 ° С.. + 30 ° С, off. If OFF is selected, temperature 

control will not be performed while the timer is running.

Summary of Contents for Freshbox 200 ERV WiFi

Page 1: ...USER S MANUAL EN Air handling unit Freshbox 200 ERV WiFi Freshbox E 200 ERV WiFi Freshbox E1 200 ERV WiFi Freshbox E2 200 ERV WiFi ...

Page 2: ...e and operating staff The manual contains information about the purpose technical details operating principle design and installation of the Freshbox E E1 E2 200 ERV WiFi unit s and all of its their modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as we...

Page 3: ...water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open ...

Page 4: ...tures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED O...

Page 5: ...6 75 70 68 67 66 75 70 68 67 66 Heat exchanger type Counter flow Heat exchanger material Enthalpy membrane Supply filter G4 F7 H13 optional Extract filter G4 Connected air duct diameter mm 100 Weight kg 44 The unit is designed for indoor application with the ambient temperature ranging from 1 C up to 40 C and relative humidity up to 70 In order to prevent condensation on the internal walls of the ...

Page 6: ...www blaubergventilatoren de Freshbox E E1 E2 200 ERV WiFi 6 B A C F E ØD Model Dimensions mm Ø D A B C E F Freshbox E E1 E2 200ERVWiFi 100 1018 550 240 265 200 ...

Page 7: ...arately H13 filter option INTAKE AIR EXHAUST AIR EXTRACT AIR SUPPLY AIR Warm stale extract air from the room flows to the unit where it is filtered by the extract filter then air flows through the heat exchanger and is exhausted outside by the extract fan Cold fresh air from outside flows into the unit where it is cleaned by the supply filter Then filtered air flows through the heat exchanger and i...

Page 8: ...rage exhaust air temperature downstream of the heat exchanger is not below 5 C The reheater is switched on and off by means of a button on a sensor control panel a remote control or via a mobile application The heat exchanger overheating protection in the Freshbox 200 ERV WiFi and Freshbox E1 200 ERV WiFi unit models without a preheater is achieved by automatic supply fan speed reduction according...

Page 9: ...MANUAL BEFORE INSTALLING THE UNIT When choosing the installation site consider the minimum distances from the unit to the surfaces min 500 mm min 500 mm min 500 mm A mounting template is included in the delivery set Fix the mounting template at the required level on the wall Make marks to drill holes for air ducts unit mounting and power cable entry Before installation operations begin route neces...

Page 10: ...struction for the ventilation hood The outer ventilation hood is available separately A Insert the air ducts in the corresponding holes of the mounting template Installtheairductwiththeminimumslopeof3mmforcondensate removal To install the unit with an additional spigot insert the connecting bend into the prepared hole in the wall aligning the mounting template hole with a round end of the connecti...

Page 11: ...pigots into the corresponding air ducts installed in the wall The slope of the air ducts must be at least 3 mm Fix the unit using the supplied screws included in the delivery set The unit is fastened with four screws Install the filters the grounding cable and the protective panels back and close the unit door Install the outer ventilation hood Remove the foam excess Fill the gaps between the air ...

Page 12: ...xt current in the standard trip current row following the maximum current of the connected unit The automatic circuit breaker is not included in the delivery set Connection of unit contacts is carried out in the control unit To access the control unit open the unit door remove the protective panel undo the screws securing the side wall and remove it Connection of the automatic fire fighting system...

Page 13: ...ly schedule with factory settings The button for switching on the weekly schedule blocks the buttons for changing speeds and switching the reheating on off 5 TheWi Fi module is switched on off using Switch the Wi Fi module on off by pressing If the button is held down for more than 5 seconds it flashes and the controller goes to the Setup mode for more information on this mode see page 15 6 At the...

Page 14: ...e device The application is available for download at App Store Play Market or via the QR code App Store download link Play Market download link Wi Fi technical data Standard IEFE 802 11 b g n Frequency band GHz 2 4 Transmission power mW dBm 100 20 Network DHCP WLAN safety WPA WPA2 Following message is displayed if launching an application without connection to the unit By default the unit operate...

Page 15: ...n If you are connecting via a router search for devices in the network by pressing the button Select the connection with the required ID number Edit the connection details by pressing If necessary re name the connection and enter a unit password characters allowed 0 9 a z A Z By default the unit password is 1111 Confirm the updated details by pressing Unit password change Go to Menu Connection At ...

Page 16: ...nter the password for the Wi Fi home router access point Select an IP address type DHCP the IP address is set up automatically upon connection to the home router recommended Static enables manual entry of the desired IP address subnet mask and default gateway These settings are recommended for expert users only Select this IP address type at your own risk Then press the APPLY button Special Setup ...

Page 17: ...any loss of Internet connection provided by the home server may result in temporary loss of communication with the unit To manage the unit create a new account Open the mobile app and go to MENU CONNECTION THROUGH CLOUD SERVER Press the ADD NEW ACCOUNT button Enter a login a password and an e mail address for password recovery Confirm the updated details by pressing Follow the link sent to the e m...

Page 18: ...e switching off the unit Boost Boost mode operation indicator Sensor readings Current temperature of the selected sensor which controls the air temperature Control buttons Unit on Standby 1 Selection of pre set speed Timer activation Timer settings are made in the Basic Settings Timers menu Week scheduled operation mode activation The settings of this mode are made in the Basic settings Schedule m...

Page 19: ...igital input Boost switch disappears on the control board Boost turn on delay determines the turn on delay time for the Boost mode after the signal is applied to the digital input Boost switch Schedule The weekly schedule can be set by means of 4 time intervals available for each day of the week Adjustment can be made for every day weekdays weekends or for the whole week When the Schedule mode is ...

Page 20: ... device will be automatically set Filter Filter timer setpoint when the set time 70 365 days has elapsed the filter change indicator appears and filter replacement information is displayed in the Alarms menu Run time displays the running time of the unit which cannot be reset Other The backlight brightness changes dynamically after releasing the button the brightness decreases to a preset level So...

Page 21: ...e current status of all sensors outdoor air temperature supply air temperature extract air temperature upstream of the heat exchanger exhaust air temperature downstream of the heat exchanger Boost mode sensor Fire alarm sensor Pre heater thermostat sensor Main heater thermostat sensor Firmware This section displays the current version and date of the controller and control board firmware ...

Page 22: ...rm Shortening in the outdoor temperature sensor circuit 4 Alarm No supply air temperature sensor detected 5 Alarm Shortening in the supply air temperature sensor circuit 6 Alarm No extract air temperature sensor upstream of the heat exchanger detected 7 Alarm Shortening in the circuit of the extract air temperature sensor upstream of the heat exchanger 8 Alarm No exhaust air temperature sensor det...

Page 23: ...ock even in case of regular maintenance of the filters To maintain the high heat recovery efficiency regular cleaning is required Periodical dry cleaning is recommended Use a vacuum cleaner with a narrow nozzle Remove the protective panels see page 11 Remove the clogged heat exchanger out of the unit clean it with a vacuum cleaner and install the heat exchanger back to the unit 3 Fan maintenance o...

Page 24: ...ct Noise vibration The fan impeller is soiled Clean the impellers The screw connection is loose Tighten the fastening screws STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range 5 40 С and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures pro...

Page 25: ...r s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical main...

Page 26: ...www blaubergventilatoren de Freshbox E E1 E2 200 ERV WiFi 26 ...

Page 27: ...livery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature The Freshbox ____200 ERV WiFi unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the app...

Page 28: ...www blaubergventilatoren de B73 7EN 05 ...