CONTROL
The unit is controlled by means of a control panel on the unit casing, a remote control or via a mobile application.
Control panel
Filt
er contamination
indicat
or
Alar
m indication
Unit on/off
Fan speed up
Fan speed do
wn
Scheduled operation on/off
W
i-F
i module on/off
Ent
er
ing the S
etup mode
Reheat
er on/off
(
Fr
eshb
ox E1(E2)-100 ER
V
W
iF
i
)
1. The unit is switched on/off using
.
2. Ventilation modes can be controlled by the
and
buttons.
The
and
buttons change the ventilation mode within five speeds.
Pressing
and
simultaneously for more than 3 seconds switches the timer on/off. The speed at which the unit operates after the
timer activation and time are configured via the mobile application. The timer is configured via the mobile application (
air flow
and
time
).
3. The reheater is switched on/off using
.
4. The weekly schedule can be switched on/off by pressing the
button.
For this mode, the time must be correctly set via the mobile application. By default, the controller stores a weekly schedule with factory
settings. The button for switching on the weekly schedule blocks the buttons for changing speeds and switching the reheating on/off.
5. The Wi-Fi module is switched on/off using
.
Switch the Wi-Fi module on/off by pressing
. If the button is held down for more than 5 seconds, it flashes and the controller goes to
the
Setup mode
(for more information on this mode, see page 15).
6.
At the end of the filters’ service life, the
filter replacement indicator
on the control panel will light up notifying that filters need
to be changed.
7. In emergency situations, the unit turns off and the
indicator flashes an alarm code.
Alarm code
Alarm description
4 long flashes
Outdoor sensor is missing
3 long, 1 short flash
Outdoor sensor short circuit
2 long, 1 short, 1 long flash
Sensor downstream of the heat exchanger is missing
2 long, 2 short flashes
Short circuit of the sensor downstream of the heat exchanger
1 long, 1 short, 2 long flashes
Exhaust sensor is missing
1 long, 1 short, 1 long, 1 short flash
Exhaust sensor short circuit
1 long, 2 short, 1 long flash
Connection error
1 long, 3 short flashes
Low battery
1 short, 1 long, 1 short, 1 long flash
Wi-Fi initialization error
You may find a detailed alarm description in a mobile application.