background image

 

 

 

l)

 

The suitable precautions include decontamination before disassembling the dust collector, adequate 
filtered ventilation of the exhaust air from the room in which it is disassembled, cleaning of the 
maintenance area and suitable personal protection equipment. 

m)

 

When maintenance or repair procedures are carried out, all the contaminated elements that cannot be 
properly cleaned, must be destroyed. 

n)

 

These elements must be disposed of in sealed bags according to the applicable regulations and in 
accordance with the local laws governing the disposal of such material.  

o)

 

This procedure must also be followed when the filters have to be disposed. 

p)

 

Use only original Blastrac parts. 

q)

 

The dust collector must be yearly overhauled by a skilled technician.  

 
 
 

3.7 

Transport safety 

a)

 

Be aware of your surroundings and machine operating level. Do not side hill, do not run on steep incline, 
this could cause machine to tip over. 

b)

 

The weight of 900 DC filterunit is 860 kg, the weight of the fan is 500kg. Use a crane or lift when 
transporting the machine, use the lifting eyes / lugs of the machine.  

c)

 

Before every use check the lifting eyes/lugs and welds for: 
deformation, damages, cracks,  corrosion and wear. 

d)

 

Each lifting lug has a WLL of 1500kg. 

e)

 

Pay attention that the drive unit does not turn away during lifting of the machine. 
Hold on to the steering handle until the machine is of the ground. 

f)

 

When lifting the machine from the ground, always use the lowest lifting speed. The cables must first be 
tensioned at this speed; they must not be slack when the machine is lifted from the ground. 

g)

 

During hoisting make sure to be at a safe distance from the machine with the most optimal view on the 
machine and working environment. 

h)

 

Never stand directly below the machine. 

i)

 

When transporting the machine do so in such a manner that damage due to the effects of the use of force 
or incorrect loading and unloading is avoided. 

j)

 

The lifting eyes/lugs can also be used to fasten the machine on a pallet or during transport.  

k)

 

Chock wheels for transport and keep control handle in neutral position. Use the brakes on the wheels. 

l)

 

Don’t leave the machine unsecured on jobsites. 

m)

 

Park the machine always on a flat horizontal and levelled surface. 

n)

 

Remove the dust from the dust collector before the dust collector is transported. 

o)

 

Make sure the electrical cable and dust hose are disconnected before transport. 

p)

 

Always dispose the contents of the dust collector before the end of the working day. Observe the local 
waste disposal regulations! 

q)

 

Before the dust collector is removed from the hazardous zone, take precautions to prevent dust from 
escaping. 

r)

 

For class H and M machines, the outside of the machine should be decontaminated by cleaning and 
vacuuming methods, de-dusted before being taken out from the hazardous zone. All parts of the dust 
collector must be considered as contaminated when they are removed from the hazardous zone and 
appropriate actions must be taken to prevent dust from dispersing. 

s)

 

Always close the inlets of the dust collector when the dust hose is disconnected. 

t)

 

Store the cleaned and dry machine in a humid free room. Protect the electrical motor from moisture, heat 
dust and shocks. 

u)

 

Never use the machine for lifting persons or items. 
 

 
 

Summary of Contents for EBE 900DC

Page 1: ...Original instructions in English language OPERATING INSTRUCTIONS EBE 900DC VERSION 1 4...

Page 2: ...s Repairs Cleaning Test on By Inspection before initial operation on __________________________________________ By __________________________________________ Date of initial operation ________________...

Page 3: ...kpoints of power supply 11 4 2 Checkpoints of the machine 11 4 3 Control box 12 5 Operation 12 5 1 Starting stopping the machine 12 5 2 Work with the machine 12 5 3 Interrupting work 13 5 4 Startup Pr...

Page 4: ...ning machines grinders and or scarifying machines The 900 DC can only be used for dry cleaning It should only be used for removing noncombustible non explosive dust or substances The 900 DC must not b...

Page 5: ...r pistol Use this pistol regular to remove water from the air tank 08 Safety valve 10 bar 03 Silencer with air flow pressure regulator 09 Vacuum gauge replace filters when indicating 20cm H2O 04 Fan u...

Page 6: ...Make sure that the dust being sucked up does not contain dangerous materials such as combustible or explosive dusts or substances carcinogenic or pathogenic substances In these cases additional safet...

Page 7: ...not wear loose clothing or jewellery including rings d Stay alert watch what you are doing and use common sense when operating the machine e Always seek professional medical attention immediately in...

Page 8: ...e filter cartridges are damaged or not fixed correctly inside the chamber Do not proceed Rectify immediately t When a filter is leaking it has to be replaced The compartment above the filters and sile...

Page 9: ...ot be slack when the machine is lifted from the ground g During hoisting make sure to be at a safe distance from the machine with the most optimal view on the machine and working environment h Never s...

Page 10: ...g the machine Name address and CE mark The machine type The net weight of the machine in kilogram The year of manufacture The serial number of the machine Email address Website Telephone fax number WA...

Page 11: ...e protective earth conductor in particular in order to ensure that all safety devices are functioning and to eliminate possible damage to electrical components 4 2 Checkpoints of machine Safety functi...

Page 12: ...on the compressor motor 5 Switch on the fan motor 4 wait for the fan to get at full speed Switch on the rotating valve motor 3 Carry out this actions in opposite sequence to stop the machine 5 2 Work...

Page 13: ...it up a fault has been detected and the system has shut down If the light Phase Incorrect is lit up the phases of the power connection are wrong If the light Control Voltage is lit up the power supply...

Page 14: ...secure it with the pull strap 4 Start the rotating valves 5 6 Silencer The silencer on top of the fan unit reduces the noise emission but can also be used to adjust the suction power of the machine Cl...

Page 15: ...e upper section of the filter unit Clean or replace the air filter of the compressor Clean or replace the filter inside the water separator Check the blades of the rotating valves Check the spider cou...

Page 16: ...s Provide adequate ventilation when working in a confided space Secure the maintenance area if necessary 6 1 When to change the filters When the Pressure Diff gauge is above 20 cm H2O the filters are...

Page 17: ...r can cause serious damage to the machine and is a health hazard Never expose the filter cartridges to moisture 6 2 Changing the filters Read chapter 3 Safety before changing the filters Operators sho...

Page 18: ...suction of contaminants in the clean parts and consequently the machine blows dirt backwards in the outer air When a filter was damaged has leaked or was mounted incorrect it has to be replaced The co...

Page 19: ...7 bar is not reached it is possible that either the filter of the water separator or the air filter of the compressor is dirty If inspection of the water separator and compressor shows no abnormalitie...

Page 20: ...g 31 Filter element 36 Louver This spitter type drain operates momentarily when a rapid change in air flow occurs or when the supply pressure is reduced The separated water will be drained in the Drai...

Page 21: ...lastrac Compressor oil Part nr E00498 Prior to draining off the oil the compressor unit should have operating temperature Check oil level 2 or 3 minutes after stopping The compressor is factory filled...

Page 22: ...t must be tightened by the adjusting nuts if the gland seals are leaking dust It is important that the pressing bush is not on an angle Tighten the nuts 180 and test the rotating valves for leaking du...

Page 23: ...the rotating valves by rotating the drive motor with drive motor plate for more than 180 see figure below 3 Pull out the main plug and remove the bolts and clamp strip of the rotating valve blade 4 P...

Page 24: ...drives have to be checked every 3 months 6 8 V belt mounting Reduce the distance between the driving motor and the bearing to release the tension of the V belt drive Carefully put the V belt in the gr...

Page 25: ...n of the V belt Change or refill the oil Bad or no filter cleaning Pressure too low Pulse timer PLC defective or wrong settings See above Contact Blastrac No suction power Dirty filter cartridges Fore...

Page 26: ...kg Weight Fan unit 500 kg Pressure adjusting compressor 6 7 bar Pressure differential filter surface MAX 50 150 mm WS 2 6 inch WG Noise level at 1 mtr distance Up to 83 dB A The electrical diagrams o...

Page 27: ...tal working period Identify additional safety measures to protect the operator from the effects of noise such as proper and regular maintenance of the machine and the accessories provision of proper e...

Page 28: ...info blastrac de WWW BLASTRAC DE BLASTRAC UKRAINE SALES SERVICE CENTRE Nezalezhnosti 14 of 21 07400 Brovary Tel 38 0 44 222 51 28 Fax 38 0 44 277 98 29 Email info blastrac com ua WWW BLASTRAC COM UA B...

Reviews: