12
www.blastrac.eu
4. Initial operations
Before using the machine it is important to inspect the machine.
It is not permitted to use the machine if the machine safety is not according the checkpoints below.
Before switching on the machine make sure that no-one can be endangered when the machine starts up!
4.1
Checkpoints of electrical safety
Use only extension cables for extending the main cable that are sized and marked in accordance with
the overall power consumption of the machine.
Electrical cables must be fully unwound of them reels.
No damage is permitted for electrical cables.
Use an electrical power supply connection with earth connecting.
The main switch of the machine should be put to ‘Off’ before connecting to the power supply. (Only if
there is a main switch present on the electrobox.)
Make sure the power supply is in accordance with the machine specifications.
If the machine is to be operated using power from a generator, the generator must be operated in
accordance with the current legal regulations and directives in force. (This applies to the protective
earth conductor in particular) in order to ensure that all safety devices are functioning and to
eliminate possible damage to electrical components.
4.2
Checkpoints of machine safety
Safety functions and operating functions must work correct.
Check the diamond wings for damages and/or wear.
Check all screws and other fasteners for tightness. No loose bolts and/or nuts are permitted.
Check the electrical components, cables and connections for wear and/or damages.
Dust hose connection must be reliable: use hose clamps and industrial tape.
Dust hoses must be undamaged and free of obstructions
Make sure that the dust bin / bigbag is empty and connected properly.