background image

3

NATURAL   -    U-LPG

1 Double crown Wok burner  

15.5 MJ/h

12.6   MJ/h

2 Rapid gas burner  

12.0 MJ/h

10.4  MJ/h

3 Semirapid gas burner 

7.1  MJ/h

6.3   MJ/h

4 Semirapid reduced gas burner

5.4  MJ/h  

4.9  MJ/h

5 Auxiliary gas burner                                                         4.1  MJ/h

3.6   MJ/h

6 Cast iron pan support ( depending on the version)

7 Burner n° 1 control knob

8 Burner n° 2 control knob

9 Burner n°3 control knob

10 Burner n° 4 control knob

11 Burner n° 5 control knob

12 Ultra rapid burner *DCC AFB (Wok)                           15.5 MJ/h

12.6   MJ/h  MJ/h

13 Burner n° 12 control knob

Attention: this appliance has been manufactured for domestic use only. Do not modify this

appliance.

DESCRIPTION OF THE HOTPLATE 

BCG603WXFFC

BCG755WXFFC

BCG905WXFFC

BCG604WXFFC

Overall measurement (mm)

Width 580 x Depth 500 x Height 40

Overall measurement (mm)

Width 750 x Depth 500 x Height 40

Overall measurement (mm)

Width 860 x Depth 500 x Height 40

Overall measurement (mm)

Width 580 x Depth 500 x Height 40

*DCC AFB:

Air From 

Bottom

*DCC AFB: Air From Bottom

Summary of Contents for BCG603WXFFC

Page 1: ...functional and safety features on the products themselves If your cooktop requires service please contact the Blanco customer service centre COD 04077AX 27 10 2017 Dear Customer Thank you for purchasi...

Page 2: ...children without supervision MAINTENANCE SCHEDULE Clean the cooktop surface after every use as specified within this manual Clean burner top and trivet at least once a week or after any spillage Gas...

Page 3: ...ntrol knob 11 Burner n 5 control knob 12 Ultra rapid burner DCC AFB Wok 15 5 MJ h 12 6 MJ h MJ h 13 Burner n 12 control knob Attention this appliance has been manufactured for domestic use only Do not...

Page 4: ...in thick metal WARNINGS Burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners i...

Page 5: ...y opening a window or by increasing the power of the mechanical exhausting system if installed Do not attempt to change the technical characteristics of the product because it can be dangerous If you...

Page 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Page 7: ...0 mm above the top of the burner and no construction shall be within 450 mm above the top of the burner Aminimum depth of 70 mm from the top of the worktop surface must be provided for the appliance 3...

Page 8: ...set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn the screw F until the bracket S stick on the to...

Page 9: ...tion Unions compatible with the hose fittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural Gas Natural...

Page 10: ...d to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 taking care of respecting the following corres...

Page 11: ...refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced rate adjustment Switch on the burner and turn the relat...

Page 12: ...m panel near the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models BCG603WXFF...

Page 13: ...re regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate ta...

Page 14: ...s given in paragraph 6 FIG 16 H05 RR F Section 3 X 0 75 mm2 Gas hot plate If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Page 15: ...After Sales Service Centres and a qualified retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations give...

Page 16: ...nths on any labour cost of service or repair SERVICE AREA The provision of service under Our Warranty is limited by the boundary territory area of the nearest service centre Travelling cost incurred f...

Reviews: