CONVERSIONS

8) UNIVERSAL-LP GAS TO NATURAL

GAS CONVERSION PROCEDURE

Appliance models: Gas stainless steel hotplate

models:

BCG603WXFFC

3 Burners

BCG604WXFFC

4 Burners                    

BCG755WXFFC- BCG905WXFFC

5 Burners

1.

Remove each burner cap and burner skirt.

2.

Remove  the  U-LPG  main  injector  with  a

7 mm/VF tube spanner and replace with the

appropriate size Natural Gas main injector for each

burner. The following injector sizes are required for

Natural Gas:

Burner

Main injector

Double crown                               1.80 mm

Rapid

1.55  mm

Semi Rapid

1.20 mm

Semi Rapid Reduced                   1.05 mm

Auxiliary

0.90 Bmm

*Double crown  * DCC AFB         1.80 mm

3.

Shut off gas supply to the appliance.

4.

Disconnect gas inlet pipe from the U-LPG test

point inlet fitting.

5.

Remove the U-LPG  test point inlet fitting from

the appliance.

6.

Fit the Natural Gas Regulator supplied in the

conversion kit.

7.

Connect the gas supply to the Regulator.

8.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

9.

Adjust the gas pressure to 1.00 kPa.

10.

Remove the control knob, with a thin shaft blade

screwdriver down the centre of each gas valve

shaft, screw the by-pass injector anti-clockwise.

Test the appliance on both high and low flame for

each burner. If the burner fails to remain alight or

the flame is not stable on the simmer setting, adjust

the by-pass screw, until flame is stable.

11.

If not already removed, remove the “Only for

use with U-LPG label adhered to the bottom panel

near the gas connection.

12.

Fit the new data label included in the gas

conversion kit.

9) NATURAL GAS TO U-LPG

CONVERSION PROCEDURE

Appliance models: Gas stainless steel hotplate

models:

BCG603WXFFC

3 Burners

BCG604WXFFC

4 Burners                    

BCG755WXFFC- BCG905WXFFC

5 Burners

1. 

Remove each burner cap and burner skirt.

2.

Remove the Natural Gas main injector with a

7 mm/VF tube spanner and replace with the

appropriate size U-LPG Gas main injector for each

burner. The following injector sizes are required for

U-LPG Gas:

Burner

Main injector

Double crown                           1.00   mm

Rapid

0.91  mm

Semi Rapid

0.70 mm

Semi Rapid Reduced                0.60 mm

Auxiliary

0.53 mm

*Double crown  DCC AFB        1.00 H1 mm

3. 

Remove the control knob, with a thin shaft blade

screwdriver down the centre of each gas valve

shaft, screw the by-pass injector fully clockwise.

4.

Shut off gas supply to the appliance.

5.

Disconnect gas inlet pipe from the Natural Gas

Regulator.

6.

Remove the Natural Gas Regulator from the

appliance.

7.

Fit the U-LPG Gas test point inlet fitting supplied

in the conversion kit.

8.

Connect the gas supply to the inlet fitting.

9.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

10.

Adjust the gas pressure to 2.75 kPa.

11.

Test the appliance on both high and low flame

for each burner and check the gas pressure. If the

burner fails to remain alight or the flame is not

stable on the simmer setting, adjust the by-pass

screw until flame is stable.

12.

If not already removed, remove the “Only for

use with Natural Gas” label adhered to the bottom

panel near the gas connection.

13.

Fit the new data label included in the gas

conversion kit.

Summary of Contents for BCG603WXFFC

Page 1: ...functional and safety features on the products themselves If your cooktop requires service please contact the Blanco customer service centre COD 04077AX 27 10 2017 Dear Customer Thank you for purchasi...

Page 2: ...children without supervision MAINTENANCE SCHEDULE Clean the cooktop surface after every use as specified within this manual Clean burner top and trivet at least once a week or after any spillage Gas...

Page 3: ...ntrol knob 11 Burner n 5 control knob 12 Ultra rapid burner DCC AFB Wok 15 5 MJ h 12 6 MJ h MJ h 13 Burner n 12 control knob Attention this appliance has been manufactured for domestic use only Do not...

Page 4: ...in thick metal WARNINGS Burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners i...

Page 5: ...y opening a window or by increasing the power of the mechanical exhausting system if installed Do not attempt to change the technical characteristics of the product because it can be dangerous If you...

Page 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Page 7: ...0 mm above the top of the burner and no construction shall be within 450 mm above the top of the burner Aminimum depth of 70 mm from the top of the worktop surface must be provided for the appliance 3...

Page 8: ...set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn the screw F until the bracket S stick on the to...

Page 9: ...tion Unions compatible with the hose fittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural Gas Natural...

Page 10: ...d to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 taking care of respecting the following corres...

Page 11: ...refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced rate adjustment Switch on the burner and turn the relat...

Page 12: ...m panel near the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models BCG603WXFF...

Page 13: ...re regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate ta...

Page 14: ...s given in paragraph 6 FIG 16 H05 RR F Section 3 X 0 75 mm2 Gas hot plate If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Page 15: ...After Sales Service Centres and a qualified retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations give...

Page 16: ...nths on any labour cost of service or repair SERVICE AREA The provision of service under Our Warranty is limited by the boundary territory area of the nearest service centre Travelling cost incurred f...

Reviews: