Blagdon MIDIPOND 10000 Manual Download Page 7

MAINTENANCE & CLEANING

Polymer wool and carbon cartridge 

When the cartridge chamber fills with water and starts to overflow into the outlet chamber the cartridge

should be cleaned or replaced.

The Polymer wool pad may be washed a limited number of times before it starts to lose efficiency and

blocks rapidly.

The Carbon Foam pad contains activated carbon particles that remove colorants and chemical pollutants

from your pond water. After six weeks the activated carbon pad must be replaced as the carbon

becomes full with pollutants and will be unable to absorb more from the pond water.

Replacement packs of polymer wool and carbon foam pads will be available from your retailer and are

quick and easy to replace. (see diagram on page 8 and codes/descriptions on page 2)

Annual maintenance

Check for wear

Once a year you should dismantle your Midipond filter. Dismantle the filter examining all the parts for

wear or damage, replacing any parts show obvious signs of wear or damage. (see getting to know your

Midipond filter for replacement codes and parts descriptions on page 2).

Replacing foams

After prolonged use and cleaning the filter foams will become damaged. This can be identified by their

inability to return quickly into shape after cleaning.

Replacement of the foams is recommended.

Winter storage

The filter can be run year round if the pump flow is maintained, this is the best option. Alternatively in

winter the filter may be switched off. Follow annual maintenance procedure and store frost-free in the

house or garage until spring.

TROUBLESHOOTING

In order to correctly identify if you have green water or cloudy/brown water, a settlement test

should be carried out. 

Take a glass of pond water and allow to settle for a few hours. When the glass is stirred a small

layer of settled waste can be seen at the base of the glass. This indicates that you have brown or

cloudy water and that if you have a UVC model it is working correctly. If there is no settlement it

indicates that you have green water and the UVC is not working correctly.

Filter leaks

Check that the filter outlet nut and O ring have been correctly assembled and that they are hand tight.

Check the hosetail connecter O ring seal is fitted and aligned correctly on the end of the hosetail 

fitting and that the inlet cover is hand tight.

PTFE tape may be needed to give a water tight seal and should be applied to the inlet or outlet hosetails.

Always secure the filter inlet hose and outlet hose with a jubilee clip.

Insure that the filter is installed on a flat and level base.

Cloudy/brown water

The flow rate / pond turnover is to high or to low. Check that you have correctly calculated the pond 

volume and that pump flow rate is within limits. (see connecting your pump page 6)

The filter is not being supplied with water 24 hours a day. Do not turn off your pump or UVC. 

Continuous running is needed to maintain a clean and healthy pond.

The filter foam pads are insufficiently blocked to trap the fine waste. Treat with Interpet Clear Pond 

treatment.

Do not clean the foams until the filter foam chamber starts to overflow into the carbon wool chamber.

The water is extremely dirty, remove pond waste and leaves - carry out a partial water change.

Filter is incorrectly sized - refer to filter performance and specification chart. Calculate the pond 

volume - see connecting to your pump page 6.

The filter foams have not been positioned or replaced correctly,ensure that the foams fit tightly within 

the filter chamber.

11

10

Midipond_Inst_AW.qxd  6/2/07  3:20 pm  Page 7

Summary of Contents for MIDIPOND 10000

Page 1: ...onstrated by Blagdon s award winning range of water gardening equipment As a result Blagdon s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike Blagdon The Po...

Page 2: ...ks flow detail 9 Annual maintenance 10 Winter storage 10 Troubleshooting 11 Filter leaks 11 Cloudy brown water 11 Green water 12 UVC light not illuminated 12 Poor flow into the filter or out of the fi...

Page 3: ...Quartz sleeve 24w 1060042 25 UVC contact chamber N A 26 Inlet hose tail O ring gasket N A 27 Inlet 1 11 4 11 2 hosetail N A 28 Inlet cap N A 29 Hydroscreen complete with course sieve Spare Hydroscreen...

Page 4: ...the carbon wool cartridge should not be higher than the outlet fittings when in use See Flow detail diagram maximum outlet chamber level page 9 WARNING If there is insufficient drop in height from the...

Page 5: ...nnected WET TESTING THE FILTER IMPORTANT A wet test of the filter under operating conditions must be carried out before the UVC or electrical supply is installed Connect the filter to the pump followi...

Page 6: ...and the water layer above the foams starts to significantly overflow the partition into the cartridge chamber 25 of the pumps input may be allowed to overflow the partition into the cartridge chamber...

Page 7: ...carried out Take a glass of pond water and allow to settle for a few hours When the glass is stirred a small layer of settled waste can be seen at the base of the glass This indicates that you have br...

Page 8: ...e does not cover the filter foams screen or UVC bulb which will need replacing when worn or every 6 months If any parts are needed spares are available from your retailer IMPORTANT GUARANTEE TROUBLESH...

Reviews: