Blagdon MIDIPOND 10000 Manual Download Page 4

INSTALLATION

INSTALLATION

5

4

CONVENIENT INSTALLATION 

Can be installed below or above ground with water returned direct to the pond or via a waterfall. e.g:

ABOVE
GROUND

BELOW
GROUND

FILTER OUTLET HOSE INSTALLATION

Filter outlet
to Waterfall

MIDIPOND FILTER

(below ground)

FOUNTAIN

PUMP

HOSE

WATERFALL

PUMP

MIDIPOND

FILTER

(above ground)

Filter outlet

to Pond

FOUNTAIN

HOSE

BELOW

ABOVE

Hose to Pond

or Waterfall

Hose from

Pump

MINIMUM DROP

15cm

MAXIMUM

LENGTH

1 metre

WATER LEVEL

Filter outlet

to Waterfall

HOSE

1 metre

15cm

UVC electronics/access

must not be below

ground level

WATERFALL

IMPORTANT

The outlet hoses should be smooth bore pipe installed over as short a distance as possible with no 

kinks or bends.

We recommend that Blagdon hose is used.

The water level in the filter outlet chamber after the carbon wool cartridge should not be higher than 

the outlet fittings when in use.

See Flow detail diagram maximum outlet chamber level. (page 9)

WARNING: 

If there is insufficient drop in height from the outlet pipes or excessive bends or 

kinks this will cause the filter to drain poorly allowing the outlet chamber to fill above the 

maximum recommended level.

This will increase filter maintenance and may cause the filter to overflow.

CONNECTING INLET HOSES

The recommended hose size for

your Midipond filter is stated in

the filter performance and

specification chart.

Always secure hose with a jubilee clip.

Warming the hose in a bucket of

boiling water can aid fitting.

Always ensure that the smaller

diameter hosetail is cut off and

removed to prevent reduced filter performance.

Use the shortest possible hose lengths to minimise flow restrictions.

Avoid folds and kinks in the hose, which will reduce flow and filter performance.

Inlet to UVC

40mm

32mm

25mm

Midipond_Inst_AW.qxd  6/2/07  3:20 pm  Page 4

Summary of Contents for MIDIPOND 10000

Page 1: ...onstrated by Blagdon s award winning range of water gardening equipment As a result Blagdon s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike Blagdon The Po...

Page 2: ...ks flow detail 9 Annual maintenance 10 Winter storage 10 Troubleshooting 11 Filter leaks 11 Cloudy brown water 11 Green water 12 UVC light not illuminated 12 Poor flow into the filter or out of the fi...

Page 3: ...Quartz sleeve 24w 1060042 25 UVC contact chamber N A 26 Inlet hose tail O ring gasket N A 27 Inlet 1 11 4 11 2 hosetail N A 28 Inlet cap N A 29 Hydroscreen complete with course sieve Spare Hydroscreen...

Page 4: ...the carbon wool cartridge should not be higher than the outlet fittings when in use See Flow detail diagram maximum outlet chamber level page 9 WARNING If there is insufficient drop in height from the...

Page 5: ...nnected WET TESTING THE FILTER IMPORTANT A wet test of the filter under operating conditions must be carried out before the UVC or electrical supply is installed Connect the filter to the pump followi...

Page 6: ...and the water layer above the foams starts to significantly overflow the partition into the cartridge chamber 25 of the pumps input may be allowed to overflow the partition into the cartridge chamber...

Page 7: ...carried out Take a glass of pond water and allow to settle for a few hours When the glass is stirred a small layer of settled waste can be seen at the base of the glass This indicates that you have br...

Page 8: ...e does not cover the filter foams screen or UVC bulb which will need replacing when worn or every 6 months If any parts are needed spares are available from your retailer IMPORTANT GUARANTEE TROUBLESH...