INSTALLATION
INSTALLATION
5
4
CONVENIENT INSTALLATION
Can be installed below or above ground with water returned direct to the pond or via a waterfall. e.g:
ABOVE
GROUND
BELOW
GROUND
FILTER OUTLET HOSE INSTALLATION
Filter outlet
to Waterfall
MIDIPOND FILTER
(below ground)
FOUNTAIN
PUMP
HOSE
WATERFALL
PUMP
MIDIPOND
FILTER
(above ground)
Filter outlet
to Pond
FOUNTAIN
HOSE
BELOW
ABOVE
Hose to Pond
or Waterfall
Hose from
Pump
MINIMUM DROP
15cm
MAXIMUM
LENGTH
1 metre
WATER LEVEL
Filter outlet
to Waterfall
HOSE
1 metre
15cm
UVC electronics/access
must not be below
ground level
WATERFALL
IMPORTANT
The outlet hoses should be smooth bore pipe installed over as short a distance as possible with no
kinks or bends.
We recommend that Blagdon hose is used.
The water level in the filter outlet chamber after the carbon wool cartridge should not be higher than
the outlet fittings when in use.
See Flow detail diagram maximum outlet chamber level. (page 9)
WARNING:
If there is insufficient drop in height from the outlet pipes or excessive bends or
kinks this will cause the filter to drain poorly allowing the outlet chamber to fill above the
maximum recommended level.
This will increase filter maintenance and may cause the filter to overflow.
CONNECTING INLET HOSES
The recommended hose size for
your Midipond filter is stated in
the filter performance and
specification chart.
Always secure hose with a jubilee clip.
Warming the hose in a bucket of
boiling water can aid fitting.
Always ensure that the smaller
diameter hosetail is cut off and
removed to prevent reduced filter performance.
Use the shortest possible hose lengths to minimise flow restrictions.
Avoid folds and kinks in the hose, which will reduce flow and filter performance.
Inlet to UVC