Blagdon MIDIPOND 10000 Manual Download Page 6

MAINTENANCE & CLEANING

For permanent installations to the mains supply, it is necessary to conform to the regulations of the local

electricity authority and this would include the use of a metal or plastic conduit to protect the cable.

Attention has been drawn to the fact that special rules may exist concerning the installation of your

pond UVC (i.e. local building regulations).

This UVC must not be used in swimming pools, or areas where people are in contact with the water.

Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained

or handled. Consult a qualified electrician if in any doubt about wiring this product to the mains supply.

Electrical/Safety

UVC Warning: Caution: Dangerous Ultra Violet Radiation. The rays from the UVC lamp are 

harmful to eyes and skin.

Always turn off UVC electrical supply before any maintenance.

To protect unit from flooding, leave a minimum 5cm showing above ground level to protect UVC electrics.

Never immerse unit in water.

Locate unit 1m minimum from pond edge to ensure the filter cannot fall in.

Your Midipond filter has been designed to need

a minimum of maintenance.

When the filter system is first installed filter

cleaning may be increased for a period until

the back log of accumulated pond waste is

removed.

Routine maintenance

Hydroscreen chamber

When the hydroscreen chamber fills with water and overflows into the foam chamber, remove and wash

out under a tap. It is not necessary to remove the metal screen from its carrier for routine cleaning.

Graded foams

The filter foams only need cleaning when the foam chamber is full with water and the water layer above

the foams starts to significantly overflow the partition into the cartridge chamber.

25% of the pumps input may be allowed to overflow the partition into the cartridge chamber, prior to cleaning.

Cleaning the foams before the foam chamber overflows will result in decreased filter efficiency as the

foams work most effectively when partially blocked.

Foams may be cleaned vigorously under a running tap or hose.

Adding Interpet Bio Start after filter maintenance will help replenish these beneficial bacterial populations,

and is highly recommended during the first two months of operation when the filter is slowly being colonised.

Professional ceramic bio media

These will only need very occasional cleaning (once per year), but must be rinsed in pond water to

prevent damaging the beneficial bacteria which help maintain a healthy pond.

ELECTRICAL INSTALLATION

COARSE

FOAM

HOW IT WORKS - FLOW DETAIL

FILTER
CLEANING

MEDIUM

CERAMIC
BIO MEDIA

AERATION
CHAMBER

FOAM
CHAMBER

VENTURI

UVC

FINE

MAXIMUM
OUTLET
CHAMBER
WATER LEVEL

OUTLET
CHAMBER 

CARTRIDGE

CHAMBER 

HYDROSCREEN

CHAMBER

PARTITION

OVERFLOW

WOOL

CARBON

CARTRIDGE

OUTLET
HOSES

9

8

IMPORTANT: 

Please note all electrical work on garden lighting and power installations must comply

with part P of the building regulations. Failure to comply is a criminal offense. If the installation of this

product is not carried out by a competent electrician who is registered under the Part P self-certification

scheme then you must notify the local building control department before work begins. For further

information and guidance on this matter and other electrical installations in your home that might be

covered by the relevant legislation, contact your local authorities building control department.

MAINTENANCE & CLEANING

Midipond_Inst_AW.qxd  6/2/07  3:20 pm  Page 6

Summary of Contents for MIDIPOND 10000

Page 1: ...onstrated by Blagdon s award winning range of water gardening equipment As a result Blagdon s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike Blagdon The Po...

Page 2: ...ks flow detail 9 Annual maintenance 10 Winter storage 10 Troubleshooting 11 Filter leaks 11 Cloudy brown water 11 Green water 12 UVC light not illuminated 12 Poor flow into the filter or out of the fi...

Page 3: ...Quartz sleeve 24w 1060042 25 UVC contact chamber N A 26 Inlet hose tail O ring gasket N A 27 Inlet 1 11 4 11 2 hosetail N A 28 Inlet cap N A 29 Hydroscreen complete with course sieve Spare Hydroscreen...

Page 4: ...the carbon wool cartridge should not be higher than the outlet fittings when in use See Flow detail diagram maximum outlet chamber level page 9 WARNING If there is insufficient drop in height from the...

Page 5: ...nnected WET TESTING THE FILTER IMPORTANT A wet test of the filter under operating conditions must be carried out before the UVC or electrical supply is installed Connect the filter to the pump followi...

Page 6: ...and the water layer above the foams starts to significantly overflow the partition into the cartridge chamber 25 of the pumps input may be allowed to overflow the partition into the cartridge chamber...

Page 7: ...carried out Take a glass of pond water and allow to settle for a few hours When the glass is stirred a small layer of settled waste can be seen at the base of the glass This indicates that you have br...

Page 8: ...e does not cover the filter foams screen or UVC bulb which will need replacing when worn or every 6 months If any parts are needed spares are available from your retailer IMPORTANT GUARANTEE TROUBLESH...

Reviews: