Blagdon Inpond 5 in 1 2000 Manual Download Page 22

20

TROUBLESHOOTING & IMPORTANT

UVC light not illuminated

• 

Check all fuses / RCD and electrical connections follow electrical installation  

Faults - Problem Procedure

Before returning your Inpond to your dealer or contacting our Consumer Advice 
Department, please carry out the following steps. This will solve most problems quickly 
and easily.
1.  Ensure electrical procedures have been followed fully. Check fuses and any cable 
 

connectors/switch boxes.

2.  (a) Follow routine maintenance procedure fully. (b) Check location and connecting your  
 

pump details including flow rates. (c) Ensure that your pond volume and pump flow rate 

  

meet the maximum pond size recommended for the filter model on the filter  

 

performance and specification chart. (d) Follow troubleshooting guide.

3.  If there is a mechanical breakdown of the filter or UVC, return to the point of purchase  
 

for inspection and advice (You will need proof of purchase).

Guarantee

UV & FILTER 

This product is guaranteed against defects in material and workmanship for 3 years from the 
date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper 
use, negligence, lack of maintenance or accidental damage to either the filter or UVC. If the 
filter or UVC fails due to a manufacturing fault within this period it will be either repaired or 
replaced free of charge. Liability is limited to replacement of the faulty product only; no other 
costs will be reimbursed. The guarantee is not transferable and does not affect your statutory 
rights. This guarantee does not confer any rights other than those expressly set out above. This 
guarantee does not cover the filter foams or UVC bulb, which will need replacing when worn 
or every 6 months. If any parts are needed, spares are available from your retailer.  

Summary of Contents for Inpond 5 in 1 2000

Page 1: ...www blagdonwatergardening co uk Search Blagdon Water Gardening for support videos inpond 5 in 1 2000 Instant solution for a clear and beautiful pond...

Page 2: ...Congratulations on buying an inpond 5 in1 Manufactured with advanced technology to create a clean and healthy pond for your fish IMPORTANT Please attach proof of purchase to this manual and file in a...

Page 3: ...cal Installation Installing UVC UVC Electrical Installation Installing Inpond Maintenance and cleaning Cleaning Step by Step guides Routine Maintenance Annual Maintenance Winter storage Troubleshootin...

Page 4: ...GETTING TO KNOW YOUR INPOND 2000 1 2 3 4 5 22 23 24 25 26 27 28 14 15 16 17 18 19 20 40 41 42 36 35 34 33 32 31 30 39 38 37 2 13 12 6 7 8 9 10 1 1 29 43...

Page 5: ...ring N A 18 UVC Quartz Sleeve Holder N A 19 Pl 5W UVC Lamp 1041041 20 5W Quartz Sleeve N A 21 Outlet Locking Nut N A 22 Double Threaded Attachment N A 23 Connecting Pipe N A 24 Pump Locking Nut N A 25...

Page 6: ...AL DATA UVC 230 Volt 50 Hz 5 Watt UVC lamp 10 metre cable IP68 Approved TECHNICAL DATA LED 1 Watt THIS 5 IN 1 WILL MAINTAIN THE FOLLOWING POND SIZES THIS MODEL 1 5m 79ltrlhr 200ltrlhr 835ltrlhr 1 0m 1...

Page 7: ...your pond pump i e local building regulations These pumps must not be used in swimming pools or areas where people are in contact with the water Always disconnect the mains electricity supply whilst...

Page 8: ...ve for water leaks 3 Then unlock the yellow quartz sleeve end cap and unplug the lamp to replace if desired Warning 1 Always turn off the power before any maintenance to the UVC section 2 Always view...

Page 9: ...making sure the two looked positions are in direct line of each other See diagram on page 8 section 5 6 The unit is protected by a magnetic safety switch that prevents the UVC light from illuminating...

Page 10: ...having a contact separation of at least 3mm in all poles must be incorporated in the wiring Important Please note all electrical work on garden lighting and power installations must comply with part...

Page 11: ...be used in swimming pools or areas where people are in contact with the water Always disconnect the mains electricity supply whilst the equipment is being installed repaired maintained or handled Cons...

Page 12: ...s not empty water out of pond water feature Adjusting Flow Control Turn clockwise to increase anti clockwise to reduce flow The flow control valve is fitted with a diverter to ensure there is always p...

Page 13: ...adjustable fountain or feature control Adjusts fountain height and width 5w UVC lamp 20 ball joint adjustment to compensate for uneven pond floor Up to 38cm fountain extension pipes LED spotlight WAT...

Page 14: ...mmended hose size is 1 2 for your Inpond It is not essential but if the fit is not tight a 1 2 jubilee clip can be used to secure the hose Warming the hose in a bucket of boiling water can aid fitting...

Page 15: ...aned vigorously in a bucket of water as required The polymer wool pad should be replaced if blocked 13 Polymer wool cartridge Replacement packs of polymer wool are available from your retailer and are...

Page 16: ...er Wool Pad Cartridge Polishes the water quickly removing particles that create cloudiness Inlet Grills High surface area ideal for general pond use How it works Flow detail The water flows through th...

Page 17: ...MAINTENANCE CLEANING 15 Lift the lid from the main filter body After cleaning the filter media replace the filter lid rotating the lid locks in a clockwise direc tion to secure...

Page 18: ...TENANCE CLEANING Cleaning the impellor The Pennington Inpond 5 in 1 is centrifugal with a magnetic impellor movement driven by a watertight synchronous motor They require minimum cleaning only periodi...

Page 19: ...icular care should be taken to examine the cable entry points Annual maintenance of the UVC Check for wear Once a year you should dismantle your Inpond UVC see page 8 Ensure you have disconnected the...

Page 20: ...until they partially block The water is extremely dirty remove pond waste and leaves carry out a partial water change Filter is incorrectly sized refer to filter performance and specification chart se...

Page 21: ...ere is follow the brown cloudy water troubleshooting guide In order to check that the UVC lamp is operating Open the filter unit see page 14 15 remove the filter foams and cartridge Positioned on top...

Page 22: ...nical breakdown of the filter or UVC return to the point of purchase for inspection and advice You will need proof of purchase Guarantee UV FILTER This product is guaranteed against defects in materia...

Page 23: ...r LED lamp which may require replacing annually If any parts need replacing spares are available from your retailer Clearwater Guarantee The Clearwater guarantee will be honoured for 1 year after proo...

Page 24: ...search and development that ensures excellent product performance and value for money for our customers Our products are brought together with half a century of expertise and knowledge so you can be a...

Reviews: