N 350
1
Indicator light “OK”
2 Indicator light “CHECK”
3
Earth connection
4
Fence connection
5 Fastening hole
6 230V ~ power cable
a.) Installation
Fastening hole (5) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall
with the connections at the bottom, see above picture, left part. For outside installation the device must also
be protected against exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device
WITHOUT
fence and connection to earth. The control lights flash in time to the impulses
(green or red). The device is ready for operation. If control lights do not flash, the power supply or power
supply line must be checked first. If no fault can be detected, the device should be tested by a specialist.
c.) Functional description with CONNECTED fence system (ea fence)
1
Control light
“OK”
(1)
Flashing green:
State of fence/ earth ok = output voltage > 4000V =
OK
2
Control light
“CHECK” (2)
Flashing
red:
CHECK
= State of fence faulty = output voltage
≤
4000V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5)
CHECK
= State of connection to earth faulty, see operating instructions enclosed,
possible sources of error (fig. 2, pg.5) and connection to earth (pg.4)
Connection variants:
Erdung
If the indicator light flashes faster than once per second, the appliance must be disconnected at once and
checked by a technician before it can be used again.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system
regularly, in accordance with the conditions of use, at least once per day.
-
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, warranty