Symptom/Situation
Probable Cause
Corr
ective Action
Power indicator (charger) is not
lit/displayed.
AC power supply cord not
connected to wall outlet.
Power supply cord not
connected to battery charger.
Bad power supply.
Bad fuse.
Check power supply
connections.
Replace power supply.
Replace fuse.
Battery Rejected indicator is
displayed. (Amber flashing)
Faulty condition identified.
Over discha
rge of battery.
Defective Batter
y.
Remove battery f
rom
charger and reinsert.
Allow to sit in charger for
15 minutes, then reinsert.
Replace battery.
Charger goes to ready in a short
period of time (5-15 minutes).
Battery is fully charged.
Faulty battery.
New Battery.
Try conditioning battery.
(Nickel Based Only)
Replace battery.
Remove battery f
rom charger
and reinsert.
Charger will not go into Charge
mode. (Amber solid indicator)
Battery not seated correctly.
Bad charger.
Defective batter
y.
Faulty LED.
Re-insert battery.
Replace charger.
Replace battery.
Send in for repair.
Charger will not go into
Condition mode. (Amber solid
indicator)
(NiMH only)
(Li-Ion does not condition)
Battery too hot.
Battery not designed to
condition in the charger.
Faulty LED.
Remove batter
y, allow to cool
& reinsert.
Do not condition.
Send in for repair.
Battery becomes hot
Defective batter
y.
Immediately r
emove battery
from charger and replace.
Power supply shuts down
temporarily.
Power line surge.
Power will automatically reset.