TA04678 A Page 3 of 8
2.0
PARTS & ACCESSORIES
3.0
SPECIFICATIONS
CHARGER (144-CHR-HLI)
2.1
CHARGER
3.1
POWER SUPPLY
2.2
•
Accommodates Ni-Cd / Ni-MH and
Li-Ion batteries
• Condition feature for Nickel-based
products
• Charge control inside each charger
• Power supply: Single Unit Charger:
24V @ 2.5 Amp International switching
power supply
• Agency approvals: UL/CUL
• Fault indicators for open or shorted
cells and temperature faults
POWER SUPPLY
3.2
POWERTRON ELECTRONICS CORP
(E248122), model PA1060-240T1A250,
input rated 100-240 Vac, 50/60 Hz, 1.8A;
output rated 24 Vdc, 2.5A, 60W max.
BATTERIES
3.3
Thomas & Betts batteries Cat. No.
CRCTBP, Ni-Cd rated Maximum 14.4V
dc, 1.9 Ah, and Cat. No. 144-BAT-HLI
Li-Ion rated Maximum 14.4V, 3Ah.
SINGLE UNIT CHARGER
AC POWER CORD WITH POWER SUPPLY
• Charge termination methods:
Ni-Cd / Ni-MH:
Delta temperature
Negative Delta V
Maximum voltage
Timeout
Maximum temperature
Li-Ion:
Minimum current
Timeout
temperature 68°F -77°F (20°C - 25°C).
Batteries charged in conditions above or
below room temperature will exhibit
battery cycle life and capacity below their
rated values. This also applies to the
temperature of the battery itself. Allow
batteries to adjust to room temperature
before charging.
OPERATING TEMPERATURE RANGES
CAUTION
Do not charge a battery that is below
32°F (0°C). Allow the battery to warm up
to room temperature before charging.
The operating temperature of the charger
is 32°F (0°C) - 113°F (45°C). For best
results, charge batteries at room
4.1
4.0
OPERATING INSTRUCTIONS