144-CHR-HLT

Battery Charger

Amber Green

Charging/Conditioning

100

%

 Full

Fault

Charge/

Ready

Power

Press to

Condition

TA04674  A

4.0

OPERATING INSTRUCTIONS

....Continued

Insert the battery into the charger. When 
the battery is inserted, the charging 
system begins the rapid charge cycle. 
When the charge cycle is completed, the 
“READY” indicator turns solid green, and 
the battery is fully charged. To attain 100% 
of its capacity, the battery should remain 
in the charger for 1-2 hours depending on 

the battery chemistry. A charged battery 
may be stored in the charger indefinitely.
Upon completion of the charging cycle of 
the Nickel-based battery, the charger 
switches to “Maintenance Mode” where it 
maintains the battery at 100% of its rated 
capacity. This will not damage your 
battery.

CHARGING THE BATTERY

4.4

(Nickel-based Battery Packs Only)

To condition a battery exhibiting a decrease in capacity, insert the battery into the 

charger and push and release the 

“CONDITION”

 button. The charger performs a 

complete (100%) discharge of the battery and recharges it to full available capacity, 

eliminating conditions that may cause it to perform below its rated capacity. This deep 
discharge cycle may take up to 15 hours to complete.

NOTE:

 The condition cycle should only be used once every several weeks. Performing 

the conditioning cycle on a daily or weekly basis shortens the usable life of the battery.

If conditioning the battery fails to eliminate the problem, the battery may have exceeded 
its usable life and may need replacement. Most batteries have a usable life of 
approximately 500 charge/discharge cycles under normal use.

Battery Rejection

If the Fault indicator on the Battery Status Display flashes, the battery is faulty or 
damaged. If the battery is still within its warranty period, contact your local 

Representative or Customer Service for replacement information.

See Troubleshooting table on page 12 for actions to be taken. If the rejected 

indicator continues to flash the battery should be removed and disposed of in 

accordance with local regulations.

CONDITIONING THE BATTERY

4.5

Battery Status
Display

NO LIGHT:

• Charger in stand by mode, ready for battery

SOLID AMBER:

• Battery is charging or being conditioned.

FLASHING AMBER (2 per second):

• Battery is rejected

.

SOLID GREEN:

• Battery is 100% charged.

BATTERY STATUS DISPLAY

4.3

TA04678  A  Page 5 of 12

Summary of Contents for 144-CHR-HLI

Page 1: ...E OF CONTENTS 1 0 GENERAL INFORMATION 2 1 1 ABOUT THIS GUIDE 2 1 2 DESCRIPTION 3 1 2 SAFETY GUIDELINES 3 2 0 PARTS ACCESSORIES 3 2 1 CHARGER 3 2 2 POWER CORD 3 3 0 SPECIFICATIONS 3 3 1 CHARGER 3 3 2 POWER SUPPLY 3 3 3 BATTERIES 3 4 0 OPERATING INSTRUCTIONS 3 6 4 1 OPERATING TEMPERATURE RANGES 3 4 2 POWER SUPPLY CONNECTION 4 4 3 BATTERY STATUS DISPLAY 5 4 4 CHARGING THE BATTERY 5 4 5 CONDITIONING T...

Page 2: ...along with instructions for conditioning your batteries Before using the battery charger read all instructions and cautionary markings on the battery charger battery and on any product using the battery WARNING To reduce risk of injury use this charger only with authorized products Other batteries or adapters may cause personal injury and or damage Do not expose the charger to rain snow or direct ...

Page 3: ...dc 1 9 Ah and Cat No 144 BAT HLI Li Ion rated Maximum 14 4V 3Ah SINGLE UNIT CHARGER AC POWER CORD WITH POWER SUPPLY Charge termination methods Ni Cd Ni MH Delta temperature Negative Delta V Maximum voltage Timeout Maximum temperature Li Ion Minimum current Timeout temperature 68 F 77 F 20 C 25 C Batteries charged in conditions above or below room temperature will exhibit battery cycle life and cap...

Page 4: ...orary adapter can be used to connect the grounding plug to a properly grounded two prong outlet A 110 volt adapter is shown below Connect the grounding plug on the adapter to the outlet box using the cover plate screw Use the temporary adapter only until a properly grounded three prong outlet can be installed by a qualified electrician POWER SUPPLY CONNECTION 4 2 WARNING Never alter an AC cord or ...

Page 5: ...ty eliminating conditions that may cause it to perform below its rated capacity This deep discharge cycle may take up to 15 hours to complete NOTE The condition cycle should only be used once every several weeks Performing the conditioning cycle on a daily or weekly basis shortens the usable life of the battery If conditioning the battery fails to eliminate the problem the battery may have exceede...

Page 6: ...ready in a short period of time 5 15 minutes Battery is fully charged Faulty battery New Battery Try conditioning battery Nickel Based Only Replace battery Remove battery from charger and reinsert Charger will not go into Charge mode Amber solid indicator Battery not seated correctly Bad charger Defective battery Faulty LED Re insert battery Replace charger Replace battery Send in for repair Charg...

Page 7: ...NOTES TA04678 A Page 7 of 8 ...

Page 8: ...odification of the product voids all warranties Limitations and Exclusions THE ABOVE WARRANTY IS THE SOLE WARRANTY CONCERNING THIS PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED LIABILITY FOR BREACH OF THE ABOVE WARRANTY IS LIMITED TO COST OF...

Reviews: