Laundry Installation and Setup Guide
10
I
N S T A L L
A N D
C
O N F I G U R E
L C 3 0 0 0
I
N S TA L L
A N D
C
O N F I G U R E
L C 3 0 0 0
LC3000 L
AUNDRY
R
EADER
I
NSTALLATION
Select a mounting method based on the application and the network mode of the reader. The LC3000 enclosure is
designed to mount on a wall: it can be flush-mounted (wiring can come from the interior of the wall); or it can be
surface-mounted (wiring can run through conduit on the exterior of the wall).
LC3000 Mounting Location Considerations
Use the following criteria to select the best mounting location for the LC3000:
Connect to 120 VAC @ 60 Hz. Connect only to a 15A maximum branch circuit protection or equivalent.
Use a circuit breaker or switch to disconnect power when installing or removing the LC3000.
• 120VAC power availability
• Network communications availability (RS-485 or 10/100 Base T)
• Wiring distance limitations
RS-485 Communications 4000' total per loop
10/100 Base-T Communications 300'
• Ease of cable routing to Laundry machines (if wired configuration)
• Installation height regulations
Mounting Requirements
Mounting hardware, .25” appropriate to surface.