Page 4  — English

IMPORTANT SAFETY INSTRUCTIONS

SPECIFIC SAFETY RULES

 

Use only recommended or equivalent  replacement parts 
and accessories and follow instructions in the 

Maintenance

 

section of this manual. Use of any other parts or failure 
to follow maintenance instructions may create a risk of 
shock or injury.

 

Maintain the unit per maintenance instructions in this 
Operator’s Manual.

 

Inspect the unit before each use for loose fasteners, fuel 
leaks, etc. Replace damaged parts.

DANGER:

Risk of fire and serious burns: Never remove fuel cap 
when unit is running. Shut off engine and allow the unit 
to cool at least five minutes. Remove cap slowly.

WARNING:

When this generator is used to supply a building 
wiring system:
 generator must be installed by a quali-
fied electrician and connected to a transfer switch as 
a separately derived system in accordance with NFPA 
70, National Electrical Code. The generator shall be 
connected through a transfer switch that switches all 
conductors other than the equipment grounding con-
ductor. The frame of the generator shall be connected to 
an approved grounding electrode. Failure to isolate the 
generator from power utility can result in death or injury 
to electric utility workers. 

 

Do not use this generator to provide power for emergency 
medical equipment or life support devices.

 

This generator has a neutral floating condition. This means 
the neutral conductor is not electrically connected to the 
frame of the machine.

 

Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick, 
dizzy, or weak while using the generator, shut it off and 
get to fresh air immediately. See a doctor. You may have 
carbon monoxide poisoning.

 

Place the generator on a flat, stable surface with a slope 
of no more than 4°.

 

Operate in a well-ventilated, well-lit area isolated from 
working areas to avoid noise interference.

 

Operating the generator in wet conditions could result in 
electrocution. Keep the unit dry.

 

Keep the generator a minimum of 3 feet away from all 
types of combustible material. 

 

Do not operate generator near hazardous material.

 

Do not operate generator at a gas or natural gas filling 
station.

 

Do not touch the muffler or cylinder during or immediately 
after use; they are HOT and will cause burn injury.

 

Do not allow the generator’s gas tank to overflow when 
filling. Fill to 1 in. below the top neck of the gasoline tank 
to allow for fuel expansion. Do not cover the fuel tank cap 
when the engine is running. Covering the fuel tank cap 
during use may cause engine failure and/or damage to 
the tool.

 

Do not smoke when filling the generator with gasoline.

 

Shut down the engine and allow to cool for five minutes 
before adding gasoline or lubricant to the generator.

 

Do not remove the oil dipstick or the fuel tank cap when 
the engine is running.

 

Pay close attention to all safety labels located on the 
generator.

 

Keep children a minimum of 10 feet away from the gen-
erator at all times.

 

The unit operates best in temperatures between 23°F and 
104°F with a relative humidity of 90% or less.

 

Operating voltage and frequency requirement of all 
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the 
equipment is not designed to operate within a +/- 10% 
voltage variation, and +/- 3 hz frequency variation from 
the generator name plate ratings. To avoid damage, al-
ways have an additional load plugged into the generator 
if solid state equipment (such as a television set) is used. 
A power line conditioner is recommended for some solid 
state applications.

 

For outdoor use only.

 

Save these instructions. Refer to them frequently and use 
them to instruct others who may use this product. If you loan 
someone this product, loan them these instructions also.

Summary of Contents for BM903600

Page 1: ...4 Reglas de seguridad espec ficas 4 S mbolos 5 7 Aspectos el ctricos 8 9 Caracter sticas 10 Armado 11 12 Funcionamiento 12 15 Mantenimiento 15 18 Correcci n de problemas 19 Garant a 20 21 Pedidos de p...

Page 2: ...ncador retr ctil J Air filter filtro de aire K Choke anegador L Fuel tank vapor vent v lvula antirretorno M Ground terminal terminal de conexi n a tierra N Fuel valve interruptor del motor O AC circui...

Page 3: ...in pasador del enganche Fig 6 A Handle mango B Handle release pin conjunto de pasador de afloje de mango D B A E A B C A Socket wrench llave de casquillo B Adjustable wrench llave ajustable Fig 2 1 3...

Page 4: ...mango del arrancador retr ctil A Knob perilla B Air filter cover tapa del filtro de aire C Filter element elemento de filtro D Air filter unit unidad del filtro de aire A B C D A Oil cap dipstick tap...

Page 5: ...aceite Fig 17 A Carburetor drain screw tornillo de drenaje del carburador Fig 21 B A A Fuel line conducto de combustible B Fuel filter filtro de combustible A B B A A Spark arrestor parachispas B Scr...

Page 6: ...the nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code con...

Page 7: ...n a confined space building nearopenwindows orinotherunventilatedspace where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and extremely dangerous gas can cause unco...

Page 8: ...perate in a well ventilated well lit area isolated from working areas to avoid noise interference Operating the generator in wet conditions could result in electrocution Keep the unit dry Keep the gen...

Page 9: ...llow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION Safety Alert Indicates a potential personal injury hazard Read Operator s Manual To reduce the risk of injury user...

Page 10: ...de verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos Using a generato...

Page 11: ...product including overhead Allow a minimum of 30 minutes of cool down time before storage Heat created by muffler and exhaust gases could be hot enough to cause serious burns and or ignite combustible...

Page 12: ...to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always...

Page 13: ...may damage the generator and or electrical devices connected to it ELECTRICAL POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding elect...

Page 14: ...Consult with a qualified local electrician for grounding requirements in your area LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase i...

Page 15: ...product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such al...

Page 16: ...ufficient to inflict serious injury WARNING Do not use any attachments or accessories not recom mended by the manufacturer of this product The use of attachments or accessories not recommended can res...

Page 17: ...KING ADDING LUBRICANT See Figure 7 NOTICE Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure NOTE If a separate engine manual is provided...

Page 18: ...urely Move at least 30 ft from refueling site before starting engine Do not smoke and stay away from open flames and sparks Failure to follow these instructions could result in a fire and cause seriou...

Page 19: ...inspecting cleaning or servicing the machine shut off engine wait for all moving parts to stop and discon nect spark plug wire and move it away from spark plug Allow 30 minutes of cool down time befor...

Page 20: ...nd to prevent cross threading Tighten with wrench to compress washer If spark plug is new use 1 2 turn to compress washer appropriate amount If reusing old spark plug use 1 8 to 1 4 turn for proper wa...

Page 21: ...ilter Run unit until tank is empty if needed or inspect filter prior to fill up Turn the fuel valve to the OFF position Push the fuel valve knob through the generator housing and pull down slightly to...

Page 22: ...enerator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein STOR...

Page 23: ...gasoline or refueled with bad gasoline Checkairfilterelement Cleanor replace as needed Drain fuel and carburetor Refuel with fresh gasoline AC receptacle does not work Circuit breaker is OFF Item plu...

Page 24: ...t to the gasoline engine OWT INDUSTRIES INC P O Box 35 Highway 8 Pickens SC 29671 USA BLACK MAX GENERATOR LIMITED WARRANTY ONE WORLD TECHNOLOGIES INC MAKES NO WARRANTIES REPRESENTATIONS OR PROMISES AS...

Page 25: ...corrosion and rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds 4...

Page 26: ...rra a un ngulo de a lo sumo 45 Si aun as la jabalina se encuentra con el estrato rocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo supe...

Page 27: ...nstrucci n para su manejo No haga arrancar o funcionar el motor en un espacio confinado de edificio cerca de ventana abiertas o en otro rea sin ventilaci n donde se puedan recolectar las emanaciones d...

Page 28: ...e sufrir intoxicaci n por mon xido de carbono Coloque el generador en una superficie estable horizontal con una pendiente no mayor de 4 Utilice la unidad en un rea bien ventilada e iluminada aislada d...

Page 29: ...s vapores del mismo son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corp...

Page 30: ...UNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos Using a generator indoors CAN KILL Y...

Page 31: ...o incluida la parte superior Aguarde al menos 30 minutos para el equipo se enfr e antes de guardarlo El calor generado por el silenciador y los gases de escape puede ser suficiente para causar quemadu...

Page 32: ...otencia necesaria en vatios para arrancar los motores el ctricos de C digo G no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herramient...

Page 33: ...rmente en este manual 2 Enchufe y active la primera carga preferiblemente la m xima carga que tenga 3 Deje que se estabilice la salida del generador el motor marcha uniformemente y el dispositivo acop...

Page 34: ...exi n a tierra en el rea geogr fica donde se encuentre usted PROTECCI N DE APAGADO POR BAJA CANTIDAD DE ACEITE El sensor de bajo nivel de aceite provoca la detenci n del motorcuandoelniveldelubricante...

Page 35: ...eza Usar este producto con partes da adas o faltantes puede causar lesiones serias al operador ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cua...

Page 36: ...ra causar una lesi n grave ADVERTENCIA No utilice ning n aditamento o accesorio no recomendado por el fabricante de este producto El empleo de aditamentos o accesorios no recomendados podr a causar le...

Page 37: ...de liberaci n del mango y ponga el mango en posici n hacia abajo Nuncautiliceelmangoparalevantarelgenerador Solamente se debe utilizar el mango para desplazar la unidad sobre las ruedas VERIFICACI N Y...

Page 38: ...e 25 mm 1 pulg abajo del cuello del tanque Coloque de nuevo la tapa del tanque de combustible y aseg rela ADVERTENCIA Apague siempre el motor antes de reabastecer combustible Nunca retire la tapa de c...

Page 39: ...dos en la f brica Su motor se debe volver a configurar para funcionar por sobre los 914 4 m 3 000 pies de altitud Hacer funcionar el motor conlaconfiguraci nequivocadaadeterminadaalturapuede aumentarl...

Page 40: ...d con las instrucciones indicadas en el apartado Verificaci n y abastecimiento de aceite Para conocer la cantidad de lubricante que se debe agregar consulte la secci n anterior Especificaciones del pr...

Page 41: ...onga la v lvula de combustible en la posici n OFF APAGADO Coloque un recipiente adecuado bajo el tornillo de drenaje del carburador para recibir el combustible afloje el tornillo Permita que se drene...

Page 42: ...se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento de acuerdo con los intervalo...

Page 43: ...e El motor almacenado sin tratamiento ni vaciado de gasolina o reabastecido de gasolina de mala calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combusti...

Page 44: ...9671 BLACK MAX GENERADOR GARANT A DE LIMITADA motor OWT Industries Inc niega cualquier y todo expresado o las garant as impl citas con respecto al motor de gasolina OWT INDUSTRIES INC NO OFRECEN NINGU...

Page 45: ...or volantes ventiladores pasajes de entrada de aire aletas de enfriamiento o cubiertas de enfriamiento obstruidos da ados o faltantes 4 El desgaste relacionado con la suciedad o mugre causado por el m...

Page 46: ...Page Pagina 22 NOTES NOTAS...

Page 47: ...Page Pagina 23 NOTES NOTAS...

Page 48: ...vice dealer Be sure to provide all relevant information when you call or visit Please call 1 800 726 5760 for assistance REPAIR PARTS The item manufacturing and serial numbers of this product are foun...

Reviews: