Black Max BM903600 Operator'S Manual Download Page 19

Page 15  — English

OPERATION

MOVING THE GENERATOR 

See Figure 12.

 

Turn off the generator.

 

Raise the handle to the up position.

 

Disconnect any equipment that is plugged into the gen-
erator.

 

Turn the fuel valve to the 

OFF position.

 

Allow 30 minutes of “cool down” time before storing the 
machine.

 

With your foot on the rear of the frame, tilt the machine 
toward you until it balances on the wheels, then roll the 
machine to the desired location.

LIFTING THE GENERATOR 

See Figure 13.

 

Turn off the generator.

 

Fold the handle to the down position. Never lift or carry 
this product using the handle.

 

NOTE: This tool is heavy and requires several people to 
lift. To avoid back injury, keep your knees bent and lift 
with your legs, not your back, and get help when needed.

HIGH ALTITUDE OPERATION

Your engine is configured for operation below 3,000 feet 
altitude at the factory. Your engine must be reconfigured for 
operation above 3,000 feet altitude. Operating the engine 
with the wrong engine configuration at a given altitude may 
increase its emissions, decrease fuel efficiency, degrade per-
formance, and cause irreversible damage. Engines configured 
for high altitude operation cannot be operated in standard 
altitude conditions. A qualified service center should ensure 
that your engine is properly configured for your location. 

MAINTENANCE

Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified 
repair establishment or individual with original or equivalent 
parts. Warranty and recall repairs must be performed by an 
authorized service center; please contact customer service 
for assistance. 

WARNING:

Before inspecting, cleaning or servicing the machine, shut 
off engine, wait for all moving parts to stop, and discon-
nect spark plug wire and move it away from spark plug. 
Allow 30 minutes of cool down time before performing 
any maintenance. Failure to follow these instructions 
can result in serious personal injury or property damage.

WARNING:

When servicing, use only recommended or equivalent 
replacement parts. Use of any other parts can create a 
hazard or cause product damage.

NOTICE

:

Periodically inspect the entire product for damaged, 
missing, or loose parts such as screws, nuts, bolts, caps, 
etc. Tighten securely all fasteners and caps and do not 
operate this product until all missing or damaged parts are 
replaced. Please contact customer service or a qualified 
service center for assistance.

GENERAL MAINTENANCE

Keep the generator in a clean and dry environment where it 
is not exposed to dust, dirt, moisture, or corrosive vapors. 
Do not allow the cooling air slots in the generator to become 
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can 
cause problems that will decrease the life of the generator.
To clean the unit:

 

Use a soft bristle brush and/or vacuum cleaner to loosen 
and remove dirt and debris.

 

Clean air vents with low pressure air that does not exceed 
25 psi.

 

Wipe the exterior surfaces of the generator with a damp 
cloth.

CHECKING/CLEANING AIR FILTER

See Figure 14.

For proper performance and long life, keep air filter clean.

 

Rotate knob counterclockwise to release. Remove cover 
and set aside.

 

Remove the filter element. 

 

If the filter element is dirty, clean with warm, soapy water. 
Rinse and let dry. 

 

Apply a light coat of engine lubricant to the element, then 
squeeze it out.

 

Replace the element in the air filter unit.

Summary of Contents for BM903600

Page 1: ...4 Reglas de seguridad espec ficas 4 S mbolos 5 7 Aspectos el ctricos 8 9 Caracter sticas 10 Armado 11 12 Funcionamiento 12 15 Mantenimiento 15 18 Correcci n de problemas 19 Garant a 20 21 Pedidos de p...

Page 2: ...ncador retr ctil J Air filter filtro de aire K Choke anegador L Fuel tank vapor vent v lvula antirretorno M Ground terminal terminal de conexi n a tierra N Fuel valve interruptor del motor O AC circui...

Page 3: ...in pasador del enganche Fig 6 A Handle mango B Handle release pin conjunto de pasador de afloje de mango D B A E A B C A Socket wrench llave de casquillo B Adjustable wrench llave ajustable Fig 2 1 3...

Page 4: ...mango del arrancador retr ctil A Knob perilla B Air filter cover tapa del filtro de aire C Filter element elemento de filtro D Air filter unit unidad del filtro de aire A B C D A Oil cap dipstick tap...

Page 5: ...aceite Fig 17 A Carburetor drain screw tornillo de drenaje del carburador Fig 21 B A A Fuel line conducto de combustible B Fuel filter filtro de combustible A B B A A Spark arrestor parachispas B Scr...

Page 6: ...the nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code con...

Page 7: ...n a confined space building nearopenwindows orinotherunventilatedspace where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and extremely dangerous gas can cause unco...

Page 8: ...perate in a well ventilated well lit area isolated from working areas to avoid noise interference Operating the generator in wet conditions could result in electrocution Keep the unit dry Keep the gen...

Page 9: ...llow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION Safety Alert Indicates a potential personal injury hazard Read Operator s Manual To reduce the risk of injury user...

Page 10: ...de verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos Using a generato...

Page 11: ...product including overhead Allow a minimum of 30 minutes of cool down time before storage Heat created by muffler and exhaust gases could be hot enough to cause serious burns and or ignite combustible...

Page 12: ...to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always...

Page 13: ...may damage the generator and or electrical devices connected to it ELECTRICAL POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding elect...

Page 14: ...Consult with a qualified local electrician for grounding requirements in your area LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase i...

Page 15: ...product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such al...

Page 16: ...ufficient to inflict serious injury WARNING Do not use any attachments or accessories not recom mended by the manufacturer of this product The use of attachments or accessories not recommended can res...

Page 17: ...KING ADDING LUBRICANT See Figure 7 NOTICE Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure NOTE If a separate engine manual is provided...

Page 18: ...urely Move at least 30 ft from refueling site before starting engine Do not smoke and stay away from open flames and sparks Failure to follow these instructions could result in a fire and cause seriou...

Page 19: ...inspecting cleaning or servicing the machine shut off engine wait for all moving parts to stop and discon nect spark plug wire and move it away from spark plug Allow 30 minutes of cool down time befor...

Page 20: ...nd to prevent cross threading Tighten with wrench to compress washer If spark plug is new use 1 2 turn to compress washer appropriate amount If reusing old spark plug use 1 8 to 1 4 turn for proper wa...

Page 21: ...ilter Run unit until tank is empty if needed or inspect filter prior to fill up Turn the fuel valve to the OFF position Push the fuel valve knob through the generator housing and pull down slightly to...

Page 22: ...enerator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein STOR...

Page 23: ...gasoline or refueled with bad gasoline Checkairfilterelement Cleanor replace as needed Drain fuel and carburetor Refuel with fresh gasoline AC receptacle does not work Circuit breaker is OFF Item plu...

Page 24: ...t to the gasoline engine OWT INDUSTRIES INC P O Box 35 Highway 8 Pickens SC 29671 USA BLACK MAX GENERATOR LIMITED WARRANTY ONE WORLD TECHNOLOGIES INC MAKES NO WARRANTIES REPRESENTATIONS OR PROMISES AS...

Page 25: ...corrosion and rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds 4...

Page 26: ...rra a un ngulo de a lo sumo 45 Si aun as la jabalina se encuentra con el estrato rocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo supe...

Page 27: ...nstrucci n para su manejo No haga arrancar o funcionar el motor en un espacio confinado de edificio cerca de ventana abiertas o en otro rea sin ventilaci n donde se puedan recolectar las emanaciones d...

Page 28: ...e sufrir intoxicaci n por mon xido de carbono Coloque el generador en una superficie estable horizontal con una pendiente no mayor de 4 Utilice la unidad en un rea bien ventilada e iluminada aislada d...

Page 29: ...s vapores del mismo son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corp...

Page 30: ...UNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos Using a generator indoors CAN KILL Y...

Page 31: ...o incluida la parte superior Aguarde al menos 30 minutos para el equipo se enfr e antes de guardarlo El calor generado por el silenciador y los gases de escape puede ser suficiente para causar quemadu...

Page 32: ...otencia necesaria en vatios para arrancar los motores el ctricos de C digo G no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herramient...

Page 33: ...rmente en este manual 2 Enchufe y active la primera carga preferiblemente la m xima carga que tenga 3 Deje que se estabilice la salida del generador el motor marcha uniformemente y el dispositivo acop...

Page 34: ...exi n a tierra en el rea geogr fica donde se encuentre usted PROTECCI N DE APAGADO POR BAJA CANTIDAD DE ACEITE El sensor de bajo nivel de aceite provoca la detenci n del motorcuandoelniveldelubricante...

Page 35: ...eza Usar este producto con partes da adas o faltantes puede causar lesiones serias al operador ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cua...

Page 36: ...ra causar una lesi n grave ADVERTENCIA No utilice ning n aditamento o accesorio no recomendado por el fabricante de este producto El empleo de aditamentos o accesorios no recomendados podr a causar le...

Page 37: ...de liberaci n del mango y ponga el mango en posici n hacia abajo Nuncautiliceelmangoparalevantarelgenerador Solamente se debe utilizar el mango para desplazar la unidad sobre las ruedas VERIFICACI N Y...

Page 38: ...e 25 mm 1 pulg abajo del cuello del tanque Coloque de nuevo la tapa del tanque de combustible y aseg rela ADVERTENCIA Apague siempre el motor antes de reabastecer combustible Nunca retire la tapa de c...

Page 39: ...dos en la f brica Su motor se debe volver a configurar para funcionar por sobre los 914 4 m 3 000 pies de altitud Hacer funcionar el motor conlaconfiguraci nequivocadaadeterminadaalturapuede aumentarl...

Page 40: ...d con las instrucciones indicadas en el apartado Verificaci n y abastecimiento de aceite Para conocer la cantidad de lubricante que se debe agregar consulte la secci n anterior Especificaciones del pr...

Page 41: ...onga la v lvula de combustible en la posici n OFF APAGADO Coloque un recipiente adecuado bajo el tornillo de drenaje del carburador para recibir el combustible afloje el tornillo Permita que se drene...

Page 42: ...se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento de acuerdo con los intervalo...

Page 43: ...e El motor almacenado sin tratamiento ni vaciado de gasolina o reabastecido de gasolina de mala calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combusti...

Page 44: ...9671 BLACK MAX GENERADOR GARANT A DE LIMITADA motor OWT Industries Inc niega cualquier y todo expresado o las garant as impl citas con respecto al motor de gasolina OWT INDUSTRIES INC NO OFRECEN NINGU...

Page 45: ...or volantes ventiladores pasajes de entrada de aire aletas de enfriamiento o cubiertas de enfriamiento obstruidos da ados o faltantes 4 El desgaste relacionado con la suciedad o mugre causado por el m...

Page 46: ...Page Pagina 22 NOTES NOTAS...

Page 47: ...Page Pagina 23 NOTES NOTAS...

Page 48: ...vice dealer Be sure to provide all relevant information when you call or visit Please call 1 800 726 5760 for assistance REPAIR PARTS The item manufacturing and serial numbers of this product are foun...

Reviews: