3
1
5
4
2
warning:
use of this tool can generate and/or disperse dust, which may
cause serious and permanent respiratory or other injury. Always use NIOSH/
OSHA approved respiratory protection appropriate for the dust exposure. Direct
particles away from face and body.
• wear appropriate hearing protection during use. Under some conditions and
duration of use, noise from this product may contribute to hearing loss.
warning:
always use safety glasses. everyday eye glasses are not safety
glasses. also use face or dust mask if cutting operation is dusty.
always wear certified safety eQuipMent:
• ANSI Z87.1 eye protection (CAN/CPA Z94.3),
• ANSI S12.6 (S3.19) hearing protection,
• NOSH/OSHA respiratory protection.
syMbols
The label on your tool may include the following symbols. The symbols and their definitions are as
follows:
V ..................volts A ...................amperes
Hz ................hertz W ..................watts
min ..............minutes
or AC .......alternating current
or DC ...direct current
no .................no load speed
................Class I Construction
.................earthing terminal
(grounded)
................safety alert symbol
................Class II Construction
.../min or rpm...revolutions or
(double insulated)
reciprocations per minute
............Read instruction manual before use
....................Use proper respiratory protection
................Use proper eye protection
.................Use proper hearing protection
•
When using an extension
cord, be sure to use one heavy
enough to carry the current
your product will draw. An
undersized cord will cause a
drop in line voltage resulting in
loss of power and overheating.
The following table shows the
correct size to use depending
on cord length and nameplate
ampere rating. If in doubt, use
the next heavier gage. The
smaller the gage number, the
heavier the cord.
4
functional description
1. Variable speed trigger
2. Forward/reverse button
3. Chuck
4. Belt clip
5. Lock-on button
Minimum gage for cord sets
volts
total length of cord in feet
120V
0-25
26-50
51-100
101-150
(0-7,6m) (7,6-15,2m) (15,2-30,4m) (30,4-45,7m)
240V
0-50
51-100 101-200
201-300
(0-15,2m) (15,2-30,4m) (30,4-60,9m) (60,9-91,4m)
ampere rating
More Not more
American Wire Gage
Than Than
0 - 6
18
16
16
14
6 - 10
18
16
14
12
10 - 12
16
16
14
12
12 - 16
14
12
Not Recommended