background image

Page 18

SET UP & USE

OPERATING INSTRUCTIONS

The unit can be controlled by the unit 
control alone or with the remote.

NOTE: 

 The outline of the operation panel 
is based on typical model, the 
function is the same with your air 
conditioner while there may be some 
slight differences in appearance.

TO TURN UNIT ON OR OFF:

 

Press ON/OFF button to turn unit on or off. 

NOTE:  

The unit will initiate automatically 
the Energy Saver function under 
Cool, Dry and Auto modes.

TO CHANGE TEMPERATURE 
SETTING: 

Press UP/DOWN button to change 
temperature setting.

NOTE:

  Press or hold either UP or 

DOWN button until the desired 
temperature is shown on the 
display.

This temperature will be automatically 

read the actual room temperature, see To 
Operate on Fan Only section.

SLEEP FEATURE:

 

Press Sleep button to initiate the 
sleep mode. In this mode the selected 

30 minutes after the mode is selected. The 
temperature will then increase (cooling) by 

30 minutes. This new temperature will 
be maintained for 6 or 7 hours before 
it returns to the originally selected 
temperature. This ends the Sleep mode 
and the unit will continue to operate as 
originally programmed. The Sleep mode 
program can be cancelled at any time 
during operation by pressing the Sleep 
button again.

TO ADJUST FAN SPEEDS:

 

Press Fan button to select the Fan Speed 
in four steps-Auto, Low, Med or High. Each 
time the button is pressed, the fan speed 
mode is shifted. 

CHECK FILTER FEATURE:

 

feature. This feature is a reminder to clean 

The LED(light) will illuminate after 250 
hours of operation. To reset after leaning 

the light will go off.

ENERGY SAVER FEATURE:

 

Press Energy saver button to initiate this 
function. This function is available on 
COOL, DRY, AUTO (only AUTO-COOLING 
and AUTO-FAN) modes. The fan will 
continue to run for 3 minutes after the 
compressor shuts off. The fan then cycles 
on for 2 minutes at 10 minute intervals until 
the room temperature is above the set 
temperature, at which time the compressor 
turns back on and Cooling Starts.

TO SELECT THE OPERATING 
MODE:

To choose operating mode, press Mode 
button. Each time you press the button, a 
mode is selected in a sequence that goes 
from Auto, Cool, Dry and Fan. The indicator 
light beside will be illuminated and 
remained on once the mode is selected.
The unit will initiate automatically the 
Energy Saver function under Cool, Dry, 
Auto (only Auto-Cooling and Auto-Fan) 
modes.

TO OPERATE ON COOL MODE:

 

Choose Cool Mode to set the cooling 
function. Use the Up and Down buttons 
to choose the desired temperature. When 
Cool Mode is selected, the fan speed can 
be adjusted by pressing the fan button.

Summary of Contents for BD06WT

Page 1: ...chase go to www blackanddecker com instantanswers If you can t find the answer or do not have access to the Internet call 844 299 0879 from 10 30 a m to 6 30 p m EST Mon Fri to speak with an agent Ple...

Page 2: ...Winter Storage 20 TROUBLESHOOTING WARRANTY Before You Call For Service 21 Customer Service 21 Troubleshooting 22 Limited Warranty 22 Thank you for purchasing our BLACK DECKER product This easy to use...

Page 3: ...or is damaged in any manner Contact an authorized service technician for examination repairs or adjustments 4 DO NOT USE AN ADAPTER OR AN EXTENSION CORD 5 Do not block airflow around the air condition...

Page 4: ...ed If ingested these batteries may leak harmful contents causing chemical burns perforation of soft tissue and in severe cases may cause death Lithium coin batteries must be removed immediately if swa...

Page 5: ...at is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the cord or plug is necessary do not connect the equipment grounding conductor to a live ter...

Page 6: ...hould trip and cut all power to the air 4 5 Press the RESET button for use You will hear a click and the A C is ready for use NOTES The RESET button must be engaged for proper use Do not use the power...

Page 7: ...ways use the switch on the control panel to start or shut off the unit Do not operate your air conditioner in a wet room such as a bathroom or laundry room Do not touch the unit with wet or damp hands...

Page 8: ...330mm BD08WT BD10WT BD12WT BD145WT 15 1 2 394mm Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner...

Page 9: ...a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radi...

Page 10: ...panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet C Once the panel has been installed on the side of the cabinet make sure it sits securel...

Page 11: ...Fig 8B NOTE Before driving the screws use a drill to drill 5 holes through the holes in the frame lock and frame extensions into the windows sash as shown Fig 8B C To secure lower sash in place attac...

Page 12: ...al from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock With 2 people keeping a rm grip on air conditioner raise sash and carefully remove Be carefull...

Page 13: ...ing 2 Set the selector control to the highest COOL setting comfortable AIR DIRECTIONAL LOUVERS Right throughout the room as needed Pivot horizontal louvers until the desired Up Down direction is obtai...

Page 14: ...Page 15 SET UP USE TIMER SPEED ONE TOUCH SLEEP ENERGY SAVER MODE TIMER SPEED ONE TOUCH SLEEP ENERGY SAVER MODE Horizontal Louvers Remote Control Control Panel Control Panel Filter PARTS FEATURES...

Page 15: ...ock sign Coin Groove Battery cover Unlock sign Lock sign Coin WARNING Danger of explosion if battery is incorrectly replaced Observe correct polarity and when replacing batteries Do not store or carry...

Page 16: ...speed Its setting is 80 F 26 C Any timer programs will be canceled SLEEP BUTTON Press this button to activate the Sleep mode This function is available on COOL HEAT or AUTO mode only and maintain the...

Page 17: ...g operation by pressing the Sleep button again TO ADJUST FAN SPEEDS Press Fan button to select the Fan Speed in four steps Auto Low Med or High Each time the button is pressed the fan speed mode is sh...

Page 18: ...p to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous temperature...

Page 19: ...washing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water...

Page 20: ...ts safely in accordance with an industry recognized assessment Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other s...

Page 21: ...ar blockage in front of unit An open doors windows or register may allow cold air to escape Close any doors winows or registers The room may be too warm Allow additional time to remove Stored Air cond...

Page 22: ...calls to repair or replace the house fuse reset a circuit breaker or correct the wiring in the house 4 Service calls required due to improper installation REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS...

Page 23: ...trademarks of The Black Decker Corporation used under license All rights reserved Product in this box may differ slightly from that pictured Does not affect function Not all accessories shown in photo...