Safety information
• For use in dry, oil free indoor environments only.
• Do not use to link between buildings.
• Not suitable for use in hazardous or explosive environments or next to highly
flammable materials.
• Ensure that all twisted pair interconnect cables are installed in compliance
with all applicable wiring regulations.
• Do not connect the CATx link interface (RJ45 style connector) to any other
equipment, particularly network or telecommunications equipment.
• Where possible, avoid laying the twisted pair link cable(s) alongside power
cables.
• Warning – the power adapter contains live parts.
• No user serviceable parts are contained within the power adapter - do not
dismantle.
• The primary means to cease operation of the modules is to remove the
power adapter lead. Ensure that the power adapter is positioned near to the
equipment and is easily accessible.
• Do not use the power adapter if the power adapter case becomes damaged,
cracked or broken or if you suspect that it is not operating properly.
• Replace the power adapter with a manufacturer approved type only.
• If you use a power extension cable with the modules, make sure the total
ampere rating of the devices plugged into the extension cable do not exceed
the cable’s ampere rating. Also, make sure that the total ampere rating of
all the devices plugged into the wall outlet does not exceed the wall outlet’s
ampere rating.
• Do not attempt to service the modules yourself.
• The modules and power supplies can get warm in operation – do not situate
them in an enclosed space without any ventilation.
• The modules do not provide ground isolation and should not be used for
any applications that require ground isolation or galvanic isolation.
• Use only with grounded outlets at both the computer and monitor. When
using a backup power supply (UPS), power the computer, the monitor and
the module from the same supply.
• For correct operation, the transmitter and receiver modules must have
ground connections. At the computer end, this is achieved by ensuring that
the computer that the module is connected to has a ground connection. At
the audio/visual device end, this can be achieved by ensuring that the power
supply is connected to a grounded power outlet. Alternatively, a ground
connection will be made via the monitor, if the monitor is itself grounded.
Products in the Wizard AVU range
The following items are available within the Wizard AVU product range:
•
Wizard AVU5010A (part number: BB AVU5010A)
One Wizard AVU5001A transmitter and one Wizard AVU5011A receiver.
•
Wizard AVU5001A transmitter (part number: BB AVU5001A)
Single Wizard AVU5001A transmitter.
•
Wizard AVU5011A receiver (part number: BB AVU5011A)
Single Wizard AVU5011A receiver.
•
Wizard AVU5004A transmitter (part number: BB AVU5004A)
Single Wizard AVU5004A transmitter.
•
Wizard AVU5111A receiver (part number: BB AVU5111A)
Single Wizard AVU5111A receiver.
•
Rack mount chassis (part number: BB AVU5000A)
One 19” chassis, 3U high and capable of accommodating up to sixteen
Wizard AVU transmitter or receiver modules.
•
Rack mount plate (part number: BB AVU5002)
Fascia plate to secure any module into the rack mount chassis.