Chapter 1: Specifications
1. Specifications
1.1 General Specifications
Distance (Maximum) —
TE160A-R2–TE163A-R2: Multimode: 3.1 mi. (4.9 km);
TE164A-R2–TE165A-R2: Single-mode: 12.4 mi. (19.9 km)
Input Power —
TE160A-R2–TE163A-R2: Multimode: -14.0 dBm;
TE164A-R2, TE165A-R2: Single-mode: -8.0 dBm
Link Budget —
TE160A-R2–TE163A-R2: Multimode: 11.0 dB;
TE164A-R2–TE165A-R2: Single-mode: 16.0 dB
RX Sensitivity —
TE160A-R2–TE163A-R2: Multimode: -31.0 dBm;
TE164A-R2–TE165A-R2: Single-mode: -30.0 dBm
TX Power —
TE160A-R2–TE163A-R2: Multimode: -19.0 dBm to -14.0 dBm,
TE164A-R2–TE165A-R2: Single-mode: -15.0 dBm to -8.0 dBm
CE Approval —
Yes
Connectors —
TE160A-R2–TE161A-R2: (1) RJ-11, (1) pair of ST
®
;
TE162A-R2–TE165A-R2: (1) RJ-11, (1) pair of SC
Indicators —
(3) LEDs: Fiber link on/off; Active in use/ringing; Power on/off
Power —
Output: 12 VDC, 0.6 A from external power supply
Size —
1.9"H x 3.7"W x 4.8"D (4.8 x 9.4 x 12.2 cm)
Weight —
2 lb. (0.9 kg)
1.2 Cable Specifications
1.2.1 Copper Cable—Category I
NOTE: Either shielded (STP) or unshielded (UTP ) twisted-pair cable is acceptable.
Gauge —
24 to 22 AWG
Maximum Number of Nodes —
2
Maximum Cable Length —
16.4 ft. (5 m) for Unit A and CO;
3.1 mi. (5 km) for Unit B and telephone