32
16- OR 32-PORT 10/100 PHYSICAL LAYER ETHERNET SWITCH
All examples in this manual assume that the device number is set to 1—the device
address character in the example command strings is the “vertical bar” or pipe
character “|” (7C hex).
Some advanced commands are not shown in this manual. For details, call
Technical Support.
7.3 Expanded List of Commands
G—Store Current Settings As Preset
command string: <cr>
//|G
xxyyyyyyyy
<cr>
xx
= 2 decimal digits (01–16) specifying the preset number
yyyyyyyy
= 32-bit hexadecimal bitmask indicating which ports should be included
in this preset
bit 0 for port 1, bit 1 for port 2, etc.
example: <cr>
//|G04FFFFFFFF
<cr> store ports as preset 4
example: <cr>
//|G050000003F
<cr> store status of ports 1 through 7
as preset 5
example: <cr>
//|G1555555555
<cr> store status of all odd-numbered ports
as preset 15
H—Set Holdoff Time
command string: <cr>
//|H
xx
<cr>
xx
= 00 through FF holdoff time in Hex, 0.10-second increments
example: <cr>
//|H14
<cr> set holdoff to 2.0 seconds
NOTE
This command does not enable or disable switching with holdoff. The
holdoff time interval is set when holdoff is in effect (see the “T”, “W”,
and “X” commands).
Summary of Contents for SW595A