23 of 24
the card. Each 2U A/B Switch cards in the system MUST have a unique address, in the range
of 0x01 to 0xFF hex. Address 0x00 is invalid, and must not be used. This is a read only
variable.
[abSwitchPort] – 1.3.6.1.4.1.9477.1.4.3.1.2.SwitchIndex
A/B Switch Card port. This variable is used to control the A/B Switch Card selected port. When
set to A, the switch will connect port A to port C. When set to B, the switch will connect port B to
port C. If the addressed A/B Switch Card is not present, you will not get a response.
[abSwitchSoftwareVersion] – 1.3.6.1.4.1.9477.1.4.3.1.3.SwitchIndex
A/B Switch Card Software Version. This is a read only variable, and is limited to a maximum of
14 characters.
On a 2U A/B Switch System, the A/B Switch cards have software. Therefore, this variable may
be different, depending on the software version on each card.
[abSwitchName] – 1.3.6.1.4.1.9477.1.4.3.1.4.SwitchIndex
A/B Switch Card Identification String. The string is limited to a maximum of 14 characters.