10
®
Special configuration
Configuration
You can alter the way that the Wizard Extender modules operate to suit
your requirements. This is done using the Configuration mode and you
can affect the following settings:
•
Password setting
– allows you to lock the remote module to
prevent unauthorized system access.
•
Mouse restoration and settings
– allows you to restore mouse
operation and also to change the mouse type.
•
Video compensation
– allows you to manually adjust the video
compensation settings.
•
Miscellaneous
functions.
What are hotkeys?
Hotkeys are two normal keyboard keys that, when pressed
simultaneously with a third key, signal to the Wizard Extender modules
that you are sending a message specifically to them and not to the
computer. The hotkeys are ordinarily
and
, while the third key
determines what you want the modules to do.
If the standard
and
hotkeys are also needed for computer
tasks, you can change them for another combination using switches 2
and 3 on the REMOTE module:
2 OFF
3 OFF
Hotkeys =
and
(default setting)
2 OFF
3 ON
Hotkeys =
and
2 ON
3 OFF
Hotkeys =
and
2 ON
3 ON
Hotkeys disabled
Entering, using and exiting configuration mode
To enter and use configuration mode:
1 Simultaneously press the currently configured hotkeys (by default,
and
) along with
.
The three keyboard indicators (‘Num Lock’,
‘Caps Lock’ and ‘Scroll Lock’) will now
begin to flash in sequence to show that
you are in configuration mode.
2 Press the first letter of the required
configuration option, for instance
.
All three keyboard indicators will
illuminate continuously.
3 Press the number of the required
configuration option, for instance
.
The ‘Scroll Lock’ indicator will extinguish,
leaving the ‘Num Lock’ and ‘Caps Lock’
indicators lit.
4 Press
to confirm your option.
The three keyboard indicators (‘Num Lock’,
‘Caps Lock’ and ‘Scroll Lock’) will now
begin to flash in sequence again.
To exit from configuration mode:
1 Within configuration mode, the three keyboard indicators should
be flashing in sequence to show that the module is ready to
receive a new command.
2 Press
.
The three indicators will return to their normal states.
Num
Loc
k
Caps
Loc
k
Scroll
Loc
k
Num
Loc
k
Caps
Loc
k
Scroll
Loc
k