Appendix A - Warnings
WARNING:
THIS EQUIPMENT MUST BE EARTHED/
GROUNDED VIA THE SCREEN OF THE X.21 DTE
LEAD
This equipment relies on the EARTH/GROUND connection to ensure
EMC compliance. It must not under any circumstances be operated
without an earth connection, which could nullify its approval.
WARNING: INSTALLATION
OF
EQUIPMENT
Installation of this equipment must only be performed by suitably
trained service personnel.
This equipment allows connection only of suitably approved
equipment to its ports, the safety status of which are defined below.
SELV Ports:
i) DC
Power
ii) “To
DTE”
The above named ports are classified as SELV (Safety Extra Low
Voltage) in accordance with in Clause 2.3 of EN60950 (BS7002, IEC950
as applicable), and
must only
be connected to equipment which similarly
complies with the SELV safety classification.
The DC power port must
only be connected to the supplied power module.
TNV Ports:
i)
Euro 120 ohm RJ45
ii) 75
ohm
BNC
The above named ports are classified as TNV (Telecom Network
Voltage) in accordance with Clause 6 of EN60950 (BS7002, IEC950 as
applicable), and
must only
be connected to equipment which similarly
complies with the TNV safety classification.