11
T1/E1 FIBEROPTIC LINE DRIVER
3. Installation
3.1 General
The Line Driver is a standalone unit. Special hardware for mounting the unit
in a 19-inch rack can be ordered separately (request part number RM523). This
hardware lets you install either a single unit or two units side-by-side using minimal
rack space of 1U (1.72”) in height.
This chapter provides mechanical and electrical installation procedures for the
Line Driver. Before installing the unit, refer to
Sections 3.4
and
3.5
for internal
switch setting procedures and additional information.
If you encounter a problem, refer to
Chapter 5
for troubleshooting instructions.
3.2 What’s Included in the Package
1. After unpacking the Line Driver, inspect the unit for damage. If you notice
damage, call Black Box immediately. The package contains the following:
• Line Driver
• Power cord
• This user’s manual
2. Place the Line Driver securely on a clean surface.
3.3 Site Requirements
Install the Line Driver within 5 feet (1.5 m) of a grounded AC outlet capable
of furnishing the rated voltage of the unit (100, 115, 230 VAC or - 48 VDC).
The ambient operating temperature of the T1/E1 FOLD should be 32 to 122 °F
(0 to 50°C) at a relative humidity of up to 90%, non-condensing.