Package Contents
2-1
Chapter 2
Installation and Setup
This chapter explains how to configure and install MT1100A, MT1100A-DC,
MT1101A, MT1101A-DC, MT1102A, and MT1102A-DC converters.
After the installation is complete, refer to
Chapter 3
for information about
operating standalone units.
Refer to
Chapter 4
for troubleshooting and diagnostics information.
2.1 Site Requirements and Prerequisites
MT1100A, MT1101A, MT1102A units should be installed within 1.5m (5 ft) of an
easily-accessible grounded AC outlet capable of furnishing the required supply
voltage, in the range of 100 to 240 VAC.
MT1100A-DC, MT1101A-DC and MT1102A-DC units require a -48 VDC power
source, which must be adequately isolated from the mains supply. In order to
prevent a fire hazard, a suitable fuse must be installed in the live DC line.
Allow at least 90 cm (36 in) of frontal clearance for operator access and at least
10 cm (4 in) clearance at the rear of the unit for interface cable connections.
The ambient operating temperature should be 0 to 50°C (32 to 122°F), at a
relative humidity of up to 90%, non-condensing.
2.2 Package Contents
The package includes the following items:
•
Standalone unit or rack card
•
The AC power cord or DC power supply connector kit for standalone unit
•
Installation and operation manual on a CD
•
Rack installation kit (if ordered).