724-746-5500 | blackbox.com
Page 10
Black Box Short Range Modem
Switches S2-1 and S2-2: Word Length
Switches S2-1 and S2-2 are set in combination to determine the word length for asyn-
chronous data.
Switch S2-3: Extended Signaling Rate
The setting for switch S2-3 determines the range of variability the ME475A-R2 “looks
for” in asynchronous data rates (i.e., the actual variance from a given frequency level
the ME475A-R2 will tolerate).
Switches S2-4 and S2-5: RTS/CTS Delay
The combined settings for switches S2-4 and S2-5 determine the amount of delay
between the time the unit “sees” RTS and when it sends CTS. Options are no delay, 7
ms and 53 ms.
S2-1
S2-2
Setting
Off
On
8 bits
On
On
9 bits
Off
Off
10 bits
On
Off
11 bits
S2-3
Setting
Off
-2.5% to +1%
On
-2.5% to +2.3%
S2-4
S2-5
Setting
On
On
7 ms
Off
On
53 ms
On
Off
No delay
Off
Off
No delay
Summary of Contents for ME475A-R2