![Black Box ME475A-R2 Manual Download Page 9](http://html1.mh-extra.com/html/black-box/me475a-r2/me475a-r2_manual_2762535009.webp)
724-746-5500 | blackbox.com
Page 9
Configuration Overview
Switch S1-8: Carrier Control Method
The setting for switch S1-8 determines whether the carrier is “constantly on” or “con-
trolled by RTS”. This setting allows for operation in switched carrier, multipoint and/or
hardware handshaking applications.
2.3 CONFIGURATION SWITCH SET “S2”
The DIP switches on S2 set word length, extended signaling rate, RTS/CTS delay,
V.52 and V.54 diagnostic test and 2- and 4-wire operation.
S1-8
Setting
Off
Constantly on
On
Controlled by RTS
Table 3:
S2 Summary
Position
Function
Factory Default
S2-1
Word Length
Off
10 bits
S2-2
S2-3
Extended Signalling Rate
Off
-2.5% to 1%
S2-4
RTS/CTS Delay
On
7 ms
S2-5
S2-6
V.52/V.54 Tests
Off
Normal Operation
S2-7
2-Wire/4-Wire
Off
(4-Wire)
S2-8
Not Used
N/a
Summary of Contents for ME475A-R2
Page 1: ...ME475A R2 Async Sync Short Haul Modem...
Page 32: ...ME475A R2 version 1...