104
Modem 34336
Table 5-2. Hayes Mode Result Codes.
DIGIT
CODE
WORD
CODE MEANING
0
OK
Command line executed without errors.
1
CONNECT
Carrier detected at 0-300, 1200, or
2400 bps (basic code set).
2
RING
Ringing signal detected (in answer mode).
(When the Modem detects a ring, it
sends a RING result code unless it is in
the process of accepting a command.
However, the Modem answers the call
only if it is set for automatic answer or is
given an A command.)
3
NO CARRIER
Carrier lost or never detected.
4
ERROR
Error in command line, invalid command,
command line exceeds 40 characters, or
invalid character format.
5
CONNECT 1200 Carrier detected at 1200 bps.
6
NO DIALTONE
No dial tone detected.
7
BUSY
Busy signal detected.
8
NO ANSWER
No period of silence detected. This code
appears only if @ (wait for silence before
dialing) is included in the dial string.
10
CONNECT 2400 Carrier detected at 2400 bps.
11
CONNECT 1275 Modem is on-line in V.23 mode
(1200/75 bps).
13
CONNECT 12.0 Carrier detected at 12,000 bps.
14
CONNECT 14.4 Carrier detected at 14,400 bps.