LINESHARE MASTER-4, LINESHARE RACK
[3] Time Before First Tone
This function sets the amount of
time (waiting period) that the
Lineshare Master-4 waits before
transmitting the first tone. A time of
1.5 seconds is factory-preset, but you
can select a time from 0.5 seconds
up to 9.9 seconds.
The first digit you enter is equal to
seconds, and the second digit equals
tenths of a second. For example, an
entry of 1 2 changes the waiting
period to 1.2 seconds. An entry of 0
5 changes the waiting period to 0.5
seconds. If an entry is less than 0.5
seconds, the Lineshare Master-4
defaults to 0.5 seconds.
Example
: To set a waiting period to
2.0 seconds, enter the programming
mode and press the following on
your tone phone:
3 Time Before First Tone
2 Waiting period in seconds
0 Waiting period in tenths of a
second
(3 beeps indicate correct entry)
(optional entries for additional
changes)
# Save changes and exit
programming
[4] Number of Tones
This function sets the Number of
Tones that the Lineshare Master-4
transmits. The Number of Tones is
factory-preset to 10, but you can
select any number of tones from
1 to 99.
You must enter two digits per
entry. If the entry is less than 10,
enter a [0] in front of the single
digit. An entry of 0 9 sets the
Number of Tones to 9. An entry of 4
8 sets the Number of Tones to 48.
Example
: To set the Number of
Tones to 20, enter the programming
mode and press the following on
your tone phone:
4 Number of Tones
2 Number multiplied by 10
0 Number multiplied by 1
(3 beeps indicate correct entry)
(optional entries for additional
changes)
# Save changes and exit
programming