LINESHARE MASTER-4, LINESHARE RACK
3.2 Installing the Lineshare Master-
4 on Dedicated Data Lines
Figure 3-3
shows the Lineshare
Master-4 installed on dedicated data
lines.
To install the Lineshare Master-4
in this application, perform the
following steps:
1. Connect your phone lines to the
RJ-11 side of a patch panel.
2. Plug one end of the 24-pair telco
cable into the top right telco
connector on the back of the
patch panel.
3. Plug the other end of the 24-pair
telco cable into the telco
connector on the back of the
Lineshare Master-4 labeled
“TELCO PAIR 1-24.”
If you are using more than 24
phone lines, repeat steps 1
through 3 for the phone lines
and appropriate connectors
numbered 25-48.
4. Connect your modems to the
RJ-11 side of the patch panel.
5. Plug one end of the 24-pair telco
cable provided into the top right
telco connector on the back of
the patch panel.
6. Plug the other end of the 24-pair
telco cable into the telco
connector on the back of the
Lineshare Master-4 labeled
“MODEM PAIR 1-24.”
If you are using more than 24
phone lines, repeat steps 4
through 6 for the modems and
appropriate connectors
numbered 25-48.