background image

Black Box Hardened Managed Ethernet Switch 

 

 

RMON Statistics 

Click Port 1 ~ Port 14 to view corresponding RMON Statistics. 
 

User’s Manual                                                                                            45 

Summary of Contents for LEH808 Series

Page 1: ...ER SUPPORT INFORMATION Order toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or Fax 724 746 0746 Mail o...

Page 2: ...A valid network connection established Link ACT Flashing Transmitting or receiving data ACT stands for ACTIVITY Steady Communication speed is 100Mbps 10 100 Off Communication speed is 10Mbps 10 100 1...

Page 3: ...eb based Telnet and RS 232 console port z Support 802 3 802 3u 802 3ab 802 3z 802 3x Auto negotiation 10 100 1000Mbps full half duplex Auto MDI MDIX z 100Base FX Multi mode SC or ST type Single mode S...

Page 4: ...directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port z Configuration settings of the terminal emulation program Baud rate...

Page 5: ...Mode At the switch_a prompt just type in Enter to logon to Configure Mode or C the switch_a config prompt will show on the screen in enable and press Enter And the switch_a Configure Terminal Mode con...

Page 6: ...lack Box Hardened Managed Ethernet Switch z Enter the factory default login ID root Enter the factory default password no password Then click on the Login button to log on to the switch 6 User s Manua...

Page 7: ...esigned to deliver full scalability with SNMP RMON web based management functions by providing To get the most out of this manual you should have an understanding of Ethernet networking concepts In th...

Page 8: ...PHYSICAL PORTS SWITCH MANAGEMENT Web based browser interface 15 Administration console via RS 232 serial port CLI 15 External SNMP based network management application 15 INSTALLATION 16 SELECTING A S...

Page 9: ...THE SWITCH UNDERSTANDING THE BROWSER INTERFACE SYSTEM PORT SWITCHING TRUNKING STP RING VLAN QOS SNMP 802 1X OTHER PROTOCOLS COMMAND LINE CONSOLE MANAGEMENT 79 ADMINISTRATION CONSOLE Exec Mode View Mod...

Page 10: ...Contents When you unpack the product package you shall find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller T...

Page 11: ...nal Block z 40 to 75 40 to 167 operating temperature range Tested for functional operation 40 to 85 40 to 185 z Front panel reset button z Front panel port status LEDs z Hardened aluminum case z Suppo...

Page 12: ...02 1Q GVRP Ring z IP Multicast IGMP Snooping z Rate Control z NTP NETWORK MANAGEMENT METHODS z Console port access via RS 232 cable CLI Command Line Interface z Telnet remote access z SNMP agent MIB 2...

Page 13: ...ication 10 100TX On A valid network connection established Link ACT Flashing Transmitting or receiving data ACT stands for ACTIVITY On Communication speed is 100Mbps 10 100 Off Communication speed is...

Page 14: ...J 45 combo Gigabit Hardened Managed Ethernet Switch 12 port 10 100Base TX 1 port Gigabit Hardened Managed Ethernet Switch 12 port 10 100Base TX 2 port Gigabit Hardened Managed Ethernet Switch 8 port 1...

Page 15: ...hat lets user access full switch configuration and functionality from a Netscape or Internet Explorer browser Administration console via RS 232 serial port CLI The switch provides an onboard serial po...

Page 16: ...dequate ventilation Do not block the ventilation holes on each side of the switch it u should place the switch to extreme temperatures e Specifically the equirements een 40 C to 75 40 to 167 Connectin...

Page 17: ...Connecting to Your Network Cable Type Length It is necessary to follow the cable specifications below when connecting the switch to your network Use appropriate cables that meet your speed and cablin...

Page 18: ...pair UTP STP Cat 5 100 m 1000Base T RJ 45 2000 Mbps 4 pair UTP STP Cat 5 100 m 100Base FX Wavelength of 1300nm ST SC 200 Mbps 50 or 62 5 125 m multi mode fiber 2 km 100Base FX Wavelength of 1300nm SC...

Page 19: ...n Step 2 Prepare cable with corresponding connectors for each type of port in use Step 3 Consult Cable Specifications Table on previous page for cabling requirements based on connectors and speed Step...

Page 20: ...w Key Concepts Key Guidelines for Implementation Web Management Access Administration Console Access SNMP Access Standards Protocols and Related Reading ods that you can use to the switch It describes...

Page 21: ...gure the terminal emulation program to use the following parameters you can change these settings after login DEFAULT PARAMETERS 115 200bps 8 data bits No parity 1 stop bit This management method is o...

Page 22: ...er you set up your IP address for the switch you can access the switch s web interface applications directly in your web browser by entering the IP address of the switch You can then use your web brow...

Page 23: ...it information between reporting devices and data collection programs SNMP runs on top of the User Datagram Protocol UDP offering a connectionless mode service protocols AS TELNET rogram such as Telne...

Page 24: ...owser Management The switch provides a web based browser interface for configuring and managing the switch This interface allows you to access the switch using a preferred web browser This chapter des...

Page 25: ...or VLAN The RMON probe transfers the collected data to a management workstation on request or when a pre defined threshold is reached The management workstation collects the statistics that the RMON p...

Page 26: ...cts from layer 1 to layer 4 and as a result is the major SNMP MIB supported by all vendors in the networking industry The switch supports a complete implementation of SNMP Agent and MIB II ers of soft...

Page 27: ...roups of Bridge MIB RFC 1493 The dot1dBase Group a mandatory group that contains the objects applicable to all types of bridges The dot1dStp Group contains objects that denote the bridge s state with...

Page 28: ...his interface allows you to access the switch using a preferred web browser This chapter describes how to configure the switch using its web based browser interface Logging on to the switch SWITCH IP...

Page 29: ...User s Manual 29 PASSWORD Enter the factory default password no password Or enter a user defined password if you followed the instructions later and changed the factory default password Then click on...

Page 30: ...he switch es gro screen for configuring and SYSTEM System Information System Password IP Address Save Configuration Firmware Upgrade Reboot Logout PORT Configuration Port Status Rate Control RMON Stat...

Page 31: ...VLAN Mode Setting 802 1Q VLAN Port Setting 802 1Q Port Setting Port Based VLAN QOS Global Configuration 802 1p priority DSCP SNMP SNMP General Setting SNMP v1 v2c SNMP v3 802 1X Radius Configuration...

Page 32: ...Black Box Hardened Managed Ethernet Switch System System Information View System information VLAN ID IP Address and IP Subnet Mask of the Switch 32 User s Manual...

Page 33: ...nt system name with a new one 2 Updating setting Click Updating setting button to update your settings 3 Password Click in Password text box Type a password 4 Retype Password Click in Retype Password...

Page 34: ...choose Disable or Enable from the Default Gateway drop down list to disable or enable Default Gateway Setting for the switch Click the text box and type a new address to change the Default Gateway Ne...

Page 35: ...in FILE text box and type the name of the file that will be back upped Click Backup button to backup the file to the TFTP server 3 Save Configuration Click Save Configuration button to save your conf...

Page 36: ...in TFTP server IP text box and type the TFTP server IP address from where the file will be obtained 3 Upgrade Click upgrade button to upgrade firmware to the switch Please follow the message on the s...

Page 37: ...x Hard Ethernet Switch ened Managed Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other functions during this period of time User s M...

Page 38: ...Black Box Hardened Managed Ethernet Switch 38 User s Manual...

Page 39: ...Black Box Hardened Managed Ethernet Switch Firmware has been upgraded successfully to the switch Reboot the switch after completing the upgrade process User s Manual 39...

Page 40: ...Black Box Hardened Managed Etherne witch t S Reboot Reboot Click Reboot button to restart the switch 40 User s Manual...

Page 41: ...Black Box Hardened Managed Ethernet Switch Logout Logout Click Logout button to logout of the switch User s Manual 41...

Page 42: ...enable Admin Setting for the port 2 Speed Click Speed drop down menu to change the line speed and duplex settings from the Speed drop down list for the port 3 Flow control Click Flow control drop down...

Page 43: ...Black Box Hardened Managed Ethernet Switch Port Status View the Link Status Speed Duplex and Flow control status for all ports User s Manual 43...

Page 44: ...92kbps 1 792mbps 2mbps 3mbps 4mbps 100mbps 104mbps 112mbps 120mbps 1000mbps 2 Egress Click in Egress text box and type a new Rate to change the Egress Rate Control for the port Rate Values 64kbps 128k...

Page 45: ...Black Box Hardened Managed Ethernet Switch RMON Statistics Click Port 1 Port 14 to view corresponding RMON Statistics User s Manual 45...

Page 46: ...Black Box Hardened Managed Ethernet Switch Per Port Vlan Activities Click Port 1 Port 14 to view corresponding vlan activities 46 User s Manual...

Page 47: ...shold level 0 100 Click in Level text box and type a decimal number for the port Need to choose Broadcast and or DFL Multicast from Storm control enabled type for the port DLF Destination Lookup Failu...

Page 48: ...MAC address Click Delete MAC address drop down menu and choose a locked forwarding MAC address from the Delete MAC address drop down list to be deleted from the port 4 Submit Click Submit button when...

Page 49: ...when you finished Static MAC Entry Discard settings Port Mirroring 1 Mirror From Choose Mirror From port from Port 1 Port 14 2 Mirror To Click Mirror To drop down menu to Choose Mirror To port Port 1...

Page 50: ...runking Static Channel Group 1 Trunk 1 Click Port 1 Port 12 to assign ports to Trunk 1 Maximum 4 ports in Trunk 1 GE Trunking 1 Trunk 3 Click Static or Disable for Trunk 3 2 Submit Click Submit button...

Page 51: ...type a decimal number between 0 and 61440 3 Hello Time sec 1 9 Click in Hello Time text box and type a decimal number between 1 and 9 4 Max Age sec 6 28 Click in Max Age text box and type a decimal nu...

Page 52: ...8 4 Admin Path Cost Click in Admin Path Cost text box and enter a value between 0 and 2000000 to set the Admin Path Cost for the port 0 auto Setting 0 for the Admin Path Cost will automatically set th...

Page 53: ...state 2 Update setting Click Update setting button when you finished Ring state setting Set ring port 1 Ring port 1 Click Ring port 1 drop down menu to choose Ring port 1 from Ring port 1 drop down l...

Page 54: ...N Mode Setting 1 VLAN Mode Setting Click VLAN Mode Setting drop down menu to Choose Tag based VLAN or Port based VLAN from VLAN Mode Setting drop down list 2 Update Setting Click Update Setting button...

Page 55: ...Black Box Hardened Managed Ethernet Switch User s Manual 55...

Page 56: ...N ID textbox and specify a new VLAN ID number from 2 4094 4 VLAN Name Click in the VLAN Name textbox and type a name for this newly created VLAN Add port to or delete port from VLAN 1 VLAN Member Choo...

Page 57: ...etting The VLAN Setting window appears 2 Delete VLAN Click Delete VLAN button 3 Select a VLAN ID Click Select a VLAN ID drop down menu from Select a VLAN ID drop down list to choose the VLAN to be del...

Page 58: ...oose Access Trunk or Hybrid from Mode drop down list for the port The port will be Tag port if you choose Trunk Mode for the port And the port will be Tag or Untag port if you choose Hybrid Mode for t...

Page 59: ...Black Box Hardened Managed Ethernet Switch Port Based VLAN 1 VLAN Choose the port to be added to or deleted from the VLAN User s Manual 59...

Page 60: ...al 2 Select all Click select all button to choose Port 1 Port 14 all to be added to the VLAN 3 Delete all Click delete all button to choose Port 1 Port 14 all to be deleted from the VLAN 4 Submit Clic...

Page 61: ...the DSCP Differentiated Service Code Point labels of all traffic received on that port 3 Policy Choose Strict Priority Queue3 WRR Queue0 2 or WRR Queue0 3 A strict priority queue is always emptied fi...

Page 62: ...aged Ethernet Switch 802 1p Priority 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for VLAN Priority 0 7 2 Submit Click Submit button when you finished 802 1p pri...

Page 63: ...rdened Managed Ethernet Switch DSCP 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for DSCP Priority 0 63 2 Submit Click Submit button when you finished DSCP User...

Page 64: ...Status drop down list to choose Enable or Disable to enable or disable SNMP 2 Description Click in the Description textbox and specify a new description for SNMP 3 Location Click in the Location text...

Page 65: ...warm start trap 9 Link Down Trap Click Link Down Trap drop down menu from Link Down Trap drop down list to choose Enable or Disable to enable or disable link down trap 10 Link Up Trap Click Link Up T...

Page 66: ...Name Click in the Get Community Name textbox and specify a get community name 2 Set Community Name Click in the Set Community Name textbox and specify a set community name 3 Update Setting Click Updat...

Page 67: ...Password textbox and specify an authentication password y SNMPv3 Priv Auth MD5 Add a user using SNMP v3 with authentication and privacy Click in the Auth Password textbox and specify an authentication...

Page 68: ...n you finished SNMP V3 Setting Delete User 1 Delete User Click Delete User button The Select User Name window appears 2 Select User Name Click Select User Name drop down menu from Select User Name dro...

Page 69: ...ration 1 Radius Status Click Radius Status drop down menu from Radius Status drop down list to choose Enable or Disable to globally enable or disable authentication 2 Update Setting Click Update Setti...

Page 70: ...us server This key must match the encryption used on the radius daemon All leading spaces are ignored but spaces within and at the end of the key are used If spaces are used in the key do not enclose...

Page 71: ...ect Radius Server IP window appears 2 Select Radius Server IP Click Select Radius Server IP drop down menu from Select Radius Server IP drop down list to choose the IP address of the remote radius ser...

Page 72: ...Auto Force Authorized or Force Unauthorized to force a port state Auto specifies to enable authentication on port Force Authorized specifies to force a port to always be in an authorized state Force...

Page 73: ...Black Box Hardened Managed Ethernet Switch User s Manual 73 6 Update Setting Click Update Setting button when you finished port based authentication setting...

Page 74: ...disable GVRP GARP VLAN Registration Protocol 2 Dynamic VLAN creation Click Dynamic VLAN creation drop down menu from Dynamic VLAN creation drop down list to choose Enable or Disable to enable or disa...

Page 75: ...port Ports in the GVRP normal applicant state do not declare GVRP VLANs when in the STP blocking state 3 GVRP registration Click GVRP registration drop down menu from GVRP registration drop down list...

Page 76: ...efault 10 IGMP passive snooping 1 Report suppression Click report suppression drop down menu from report suppression drop down list to choose Enable or Disable for the switch Use this command to enabl...

Page 77: ...of NTP server 3 Sync Time Click Sync Time button to synchronize time with NTP server 4 Time Zone Click Tmie Zone drop down menu from Tmie Zone drop down list to set time zone 5 Polling Interval 1 1008...

Page 78: ...textbox and specify the offset time of daylight saving 3 Daylight Saving Tmiezone Click in the Daylight Saving Tmiezone textbox and specify the daylight saving timezone 4 Weekday Click in the textbox...

Page 79: ...pecify an Administration Console Connect the DB9 null modem or cross over cable to the RS 232 serial port of the device to the RS 232 serial port of the terminal or computer running the terminal emul...

Page 80: ...dened Managed Ethernet Switch Exec Mode View Mode Logon to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon to Exec Mode or View Mode switch_a login root 80...

Page 81: ...l or partial command string then typi displays the command keywords or ort description At the switch_a prompt just press to list the above basic commands switch_a y Access this help by typing in the n...

Page 82: ...ew Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View...

Page 83: ...Switch ed Managed E back to Exec Mode or View Mode switch_a login root Exit from Exec Mode View Mode At the switch_a prompt just type in exit and press Enter to exit from Exec Mode or View Mode switch...

Page 84: ...just type in ena Privileged Exec Mode or Enable Mode prompt will show on the screen switch_a enable le Mode Mode ble and press Enter to logon to And the switch_a Commands Privileged Exec Mode or Enabl...

Page 85: ...d Ethernet Switch At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch...

Page 86: ...or Enable Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mo...

Page 87: ...ged E back to Exec Mode or View Mode switch_a login root Exit from Privileged Exec Mode or Enable Mode At the switch_a prompt just type in exit and press Enter to exit from Privileged Exec Mode or Ena...

Page 88: ...to Configure Mode or Config And the switch_a config prompt will show on the screen switch_a configure terminal erminal Mode figure terminal and press Enter ure Terminal Mode Commands Configure Mode or...

Page 89: ...net Switch At the switch_a config prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch...

Page 90: ...d out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode At the swi...

Page 91: ...Ethernet Switch Exit from Configure Mode or Configure Terminal Mode At the switch_a config prompt just type in exit and press Enter to exit from Configure Mode or Configure Terminal Mode switch_a con...

Page 92: ...system 4 Example The following example sets the hostname to switch and shows the change in the prompt switch_a config hostname switch switch config r change the network serve le this function Passwor...

Page 93: ...subnet mask 255 255 255 0 to switch switch_a config interface vlan1 1 switch_a config if ip address 192 168 1 10 24 switch_a config if ip address IP ADDRESS no ip address IP ADDRESS no ip address IP A...

Page 94: ...ies the IP address of the DNS server 4 Example The following example sets the DNS server 192 168 1 100 to switch switch_a config ip dns 192 168 1 100 switch_a config 3 Command Syntax ip dns IP ADDRESS...

Page 95: ...p server 4 Example The following example backups configuration file to tftp server IP address 192 168 1 100 switch_a write config file 192 168 1 100 switch_a configuration file to tftp server Save Con...

Page 96: ...ompt will show on the screen switch_a config 2 Usage Use this command to enable auto save configuration function The configuration will be automatically saved at every configured interval while this c...

Page 97: ...1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use install image command to upgrade firmware from tftp serv...

Page 98: ...Black Box Hardened Managed Ethernet Switch At the switch_a prompt just type in reload and press Enter to reboot the switch after completing the upgrade process 98 User s Manual...

Page 99: ...ies restarting switch switch_a reload switch_a login Logout 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a p...

Page 100: ...able this function 3 Command Syntax no shutdown 4 Example The following example shows the use of the shutdown command to shut down the interface fe1 port 1 switch_a config interface fe1 switch_a confi...

Page 101: ...config if al Mode screen 2 Usage Use flowcontrol on command to enable flow control and configure the flow control mode for the port Use the no flowcontrol to disable this function 3 Command Syntax flo...

Page 102: ...2 Usage Use this command to specify the ingress egress rate to be used for each interface The bandwidth value is in bits Use the no parameter with this command to remove the ingress egress rate to be...

Page 103: ...nterface statistics fe1 and to display RMON face for which RMON statistics is Per Port Vlan Activities 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec...

Page 104: ...tence 4 Example The following example sets the new AGEINGTIME 1000 to bridge GROUP 1 switch_a config bridge 1 ageing time 1000 switch_a config ut time for a learned MAC address Threshold level 0 100 1...

Page 105: ...e broadcast traffic Use no storm control broadcast command to disable broadcast traffic 3 Command Syntax storm control broadcast enable no storm control broadcast 4 Example The following example shows...

Page 106: ...tch_a config if ure Terminal Mode on the screen 2 Usage Use storm control dlf enable command to enable destination lookup failure traffic Use no storm control dlf command to disable destination lookup...

Page 107: ...ing dress in the HHHH HHHH HHHH comes in GROUP 1 to forward matching the interface fe1 p Static MAC Entry Discard 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The swit...

Page 108: ...oring by the destination port on the specified source port 3 Command Syntax mirror interface SOURCEPORT direction SNOOPDIRECTION no mirror interface SOURCEPORT SOURCEPORT Name of the Source interface...

Page 109: ...nd to create a static aggregator or add a member port to an already existing static aggregator Use the no static channel group command to detach the port from the static aggregator 3 Command Syntax st...

Page 110: ...xample The following example chooses the PROTOCOL rstp on bridge GROUP 1 switch_a config bridge 1 protocol rstp vlan bridge switch_a config ng Tree protocol or Rapid Sp bridge Rapid Spanning Tree Prot...

Page 111: ...e following example enables or disables the spanning tree on bridge GROUP 1 switch_a config bridge 1 spanning tree enable switch_a config no bridge 1 spanning tree enable bridge forward switch_a confi...

Page 112: ...after which if this bridge is the root bridge all the bridges in a bridged LAN exchange Bridge Protocol Data Units BPDUs 3 Command Syntax bridge GROUP hello time HELLOTIME no bridge GROUP hello time...

Page 113: ...2 Usage Use this command to set the time in seconds after which if this bridge is the root bridge each port changes states to learning and forwarding Use the no parameter with this command to restore...

Page 114: ...terface fe1 Admin Path Cost 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the s...

Page 115: ...1 port 1 switch_a config interface fe1 switch_a config if spanning tree link type point to point switch_a config if YPE The link type to be assigned to the port point to point Enable rapid transition...

Page 116: ...no spanning tree edgeport 4 Example The following example enables the spanning tree edgeport of the interface fe1 port 1 switch_a config interface fe1 switch_a config if spanning tree edgeport switch_...

Page 117: ...e Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set Ring port 1 and Ring port 2 3 Comman...

Page 118: ...nd Mode VLAN Configure mode Logon to Configure Mode Configure Terminal Mode Logon to VLAN Configure Mode The switch_a config vlan prompt will show on the screen switch_a config vlan database switch_a...

Page 119: ...he screen switch_a config interface fe1 switch_a config if inal Mode 2 Usage Use switchport mode access command to set the switching characteristics of the Layer 2 interface to access mode and classif...

Page 120: ...ort mode hybrid acceptable frame type all switch_a config if set the switching cha to reset the mode of the Layer 2 e frame type all vlan tagged rt mode h rface fe1 port 1 Switchport mode trunk 1 Comm...

Page 121: ...outgoing frames 4 Example The following example specifies to add the interface fe1 port 1 to VLANID 2 and enable the egress tagged for the outgoing frames on interface fe1 port 1 switch_a config inte...

Page 122: ...d by a hyphen For a VLAN list specify the VLAN numbers separated by commas 4 Example The following example specifies to add the interface fe1 port 1 to VLANID 2 switch_a config interface fe1 switch_a...

Page 123: ...face fe1 switch_a config if 2 Usage Use this command to set or remove the default VLAN for the interface 3 Command Syntax switchport portbase add remove vlan VLANID VLANID The ID of the VLAN will be a...

Page 124: ...es QoS on the switch switch_a config mls qos enable switch_a config o globally enable QoS disable QoS Trust 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a c...

Page 125: ...edite expedite queue o ut Weighted Round Robin 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage...

Page 126: ...r queue cos map 1 0 1 switch_a config cify CoS v OS_VALUE DSCP 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a...

Page 127: ...ch switch_a config snmp server enable switch_a config nable and no snmp server enable Description 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prom...

Page 128: ...fig ation for SNMP loca ion for SNMP t ocation Contact 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config...

Page 129: ...ure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify trap host IP address for SNMP Use the no...

Page 130: ...on to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable warmStart command to enable warm start trap for...

Page 131: ...ommand to enable link up trap for SNMP Use the no snmp server trap type enable linkUp command to disable link up trap for SNMP 3 Command Syntax no snmp server trap type enable linkUp 4 Example The fol...

Page 132: ...server trap type enable topologyChange 4 Example The following example enables topology change trap for SNMP switch_a config snmp server trap type enable topologyChange switch_a config 4 Example The f...

Page 133: ...le specifies set community name name for SNMP switch_a config snmp server community set name switch_a config ommand to specify and no e for remove get community nam SNMP v3 SNMPv3 No Auth 1 Command Mo...

Page 134: ...r v3 user USERNAM AUTH_PASSWORD USERNAME Specify a user name ro read only access mode rw read write access mode md5 authentication method sha authentication method AUTH_PASSWORD authentication passwo...

Page 135: ...tion method AUTH_PASSWORD authentication password PRIV_PASS_PHRASE encryption pass phrase 4 Example The following example adds a user myuser using snmp v3 with read write access mode MD5 authenticatio...

Page 136: ...sable Radius Server IP Radius Server Port 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use t...

Page 137: ...4 Example The following example specifies the IP address 192 168 1 100 of the remote radius server host and set the secret key ipi shared among the radius server and the 802 1x client switch_a config...

Page 138: ...xample specifies the retransmit value 12 switch_a config radius server retransmit 12 switch_a config of time it value Enter a value in the range Port Based Authentication Authentication State 1 Comman...

Page 139: ...dot1x port control auto Specify to enable authentication on port force authorized Specify to force a port to always be in an authorized state force unauthorized Specify to force a port to always be i...

Page 140: ...x dot1x timeout re authperiod SECS no dot1x timeout re authperiod SECS 1 4294967295 Specify the seconds between reauthorization attempts The default time is 3600 seconds 4 Example The following exampl...

Page 141: ...ample globally enables GVRP to bridge GROUP 1 switch_a config set gvrp enable bridge 1 switch_a config mand to enable set and set gvrp d P globally for the bridge instance VRP in all ports of the brid...

Page 142: ...following example enables GVRP on the interface fe1 port 1 switch_a config set port gvrp enable fe1 switch_a config set port gvrp enable all IFNAME set port gvrp disable all IFNAME all All ports adde...

Page 143: ...Specify that all GVRP multicasts are deregistered and prevent any further GVRP multicast registration on the port IF_NAME The name of the interface 4 Example The following example sets GVRP registrat...

Page 144: ...Interface mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will s...

Page 145: ...ch_a config if ip igmp version 3 MP protocol version number 4 Example The following example sets the IGMP protocol version 3 on the interface fe1 port 1 switch_a config interface fe1 switch_a config i...

Page 146: ...nfigure the frequency of sending IGMP host query messages To return to the default frequency use the no ip igmp query interval command 3 Command Syntax ip igmp query interval INTERVAL no ip igmp query...

Page 147: ...nd Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interface...

Page 148: ...ace vlan1 1 switch_a config if ip igmp version 2 switch_a config if ip igmp snooping report suppression ax no ip igmp snooping report suppression 4 Example The following example enables report suppres...

Page 149: ...a config ntp server 192 168 1 100 switch_a config s or Domain name of NTP server ame of NTP s address 192 168 1 100 of NTP Sync Time 1 Command Mode Configure mode Logon to Configure Mode Configure Ter...

Page 150: ...interval 3 Command Syntax ntp polling interval MINUTE MINUTE 1 10080 The polling interval Enter a value in the range 1 to 10080 minutes 4 Example The following example specifies the polling interval 6...

Page 151: ...DAY MONTH HOUR MINUTE DAY MONTH HOUR MINUTE OFFSET TIMEZONE Specifies the daylight saving timezone DAY 1 31 Specifies from 1 to 31 MONTH 1 12 Specifies from January to December HOUR 0 23 Specifies fro...

Page 152: ...STP Cat 5 Up to 100m 328ft 50 or 62 5 125 m multi mode fiber 1300nm up to 2km 9 or 10 125 m single mode fiber 1300nm up to 75km 50 or 62 5 125 m multi mode fiber 850nm up to 550m 9 or 10 125 m single...

Page 153: ...00 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards EN61000 4 11 Voltage Dips Standards Environmental Test Compliance IEC60068 2 6...

Page 154: ...t Switch 154 User s Manual Appendix A B9 DCE pin assignment Pin no Name RS232 Signal name 1 DCD Data Carrier detect 2 RxD Received data 3 TxD Transmit data 4 N C 5 GND Signal ground 6 DSR Data set Rea...

Page 155: ...lg rid Africa Ceuta _Marino Arctic L EET 2EETDST Asia Nicosia EET Europe Minsk Europe Sofia Europe Athens Europe Vilnius Europe Chisinau Europe Istanbul Europe Kiev Europe Uzhgorod Europe Zaporozhye E...

Page 156: ...h_Dakota Center America Menominee America Costa_Rica America Managua CST6CDT US Central SystemV CST6CDT EST5EDT America New_York America Kentucky Louisville America Kentucky Monticello America Detroit...

Page 157: ...rica Porto_Acre Brazil Acre _Branco NORO2 America Noronha Brazil DeNoronha CST4CDT Antarctica Palmer America Santiago Chile Continental EIST6EIDT Pacific Easter Chile EasterIsland Asia MST 8 Asia Kual...

Page 158: ...Z GM ktu GMT UCT1 Atlantic Cape_Verde Etc GMT 1 UCT2 Atlantic South_Georgia Etc GMT 2 UCT3 Antarctica Rothera America Belem America Cayenne America Paramaribo Etc GMT 3 UCT4 America Anguilla America...

Page 159: ..._es_Salaam Africa Kampala Antarctica Syowa Asia Bahrain Asia Kuwait Asia Qatar Asia Riyadh Asia Aden Etc GMT 3 o Afri bi Indian tte Africa Mogadishu A UCT 4 Indian Mauritius Indian Reunion Indian Mahe...

Page 160: ...America Lima Mexico General ncun America M CST6 America Regina America Swift_Current Canada East Saskatchewan Canada Saskatchewan SystemV CST6 EET 2EETDST2 Europe Bucharest EET 2EETDST3 Europe Tallin...

Page 161: ...aNorte MST7MDT_MX America Chihuahua America Hermosillo America Mazatlan Mexico BajaSur CST6CDT_MX America Guatemala North America Turks and Caicos EST5EDT_TC America Grand_Turk Additions Since 10g RTM...

Reviews: