MNS-BB
Software User Guide
-124-
The output can be filtered with the help of “Show Commands”.
E.g.,
Type Syntax
:
show log informational
where “informational” is the <option> will show only
informational log entries.
----------------------------------------------------------------------------------------------
Severity Date Time
Log Description
----------------------------------------------------------------------------------------------
I 21-09-2001 11:18:18 AM Rajesh Rajesh is now on line
I 21-09-2001 11:18:18 AM Server1 network enabled on 192.168.1.16
Here is the List of System Events:
Subsystem
Description
Severity
SNTP client
started
I
SNTP
client stopped..disabled by user
I
SNTP
client stopped..server not configured
I
SNTP
Request timed out
I
SNTP Retrying..
I
DEVICE System
started
I
DEVICE
Network Stack not yet configured
I
SNMP
Snmp.snmpEnableAuthenTraps is set to enabled
A
SNMP
Snmp.snmpEnableAuthenTraps is set to disabled
A
PRTMR
Enabled by user monitor = x , sniffer = y
I
PRTMR
Disabled by user
I
VLAN
Type set to port
I
VLAN
Type set to mac
I
VLAN
Type set to tag
I
VLAN
Type set to none
I
VLAN
Pvlan: port based vlan started
I
VLAN
Pvlan: default vlan is modified
I
VLAN
Tvlan: Tag based vlan started
I
TCP/IP
Failed to initialize the interface x
F
BRIDGE
Bridge init failed for ethx
F
BRIDGE
Bridge enable for ethx failed
F
DEVICE
IP address a.b.c.d configured
I
DEVICE
subnetmask a.b.c.d configured
I
DEVICE
Default gateway a.b.c.d configured
I
DEVICE
Switch rebooted by user
I
SNMP System.sysName
configured
A
SNMP System.sysLocation
configured
A
SNMP System.sysContact
configured
A
DEVICE
Port x enabled
A
DEVICE
Port x disabled
A
CLI
Manager login at console
I
CLI
Operator login at console
I
CLI
Manager password changed
I
CLI
Operator password changed
I
SNMP
read community string changed
I
SNMP
write community string changed
I
SNMP
trap community string changed
I
RMON
rising alarm trap sent to a.b.c.d by alarm entry X
I
RMON
falling alarm trap sent to a.b.c.d by alarm entry X
I
SNMP
authentication failure trap sent to a.b.c.d
I
SNMP
Trap receiver a.b.c.d added
I
SNMP
Trap receiver a.b.c.d deleted
I
DEVICE
No saved system logs
I
DEVICE
Failed to read saved system logs
D