Chapter 3: Configuration
Page 24
724-746-5500 | blackbox.com
LGC340A
Press the down arrow on the computer keyboard to access additional
configuration selections.
WARNING
If a VLAN # is added to a port and is the same VLAN # assigned for a tag on
management traffic, saving these changes will disrupt management indefinitely.
Operation Mode 2 Port Based Xtra Tagging
Any port can be configured for extra tags on the frames.
Press the down arrow on the computer keyboard to access the additional
configuration commands.
Chapter 3: Configuration
LGC340A
724-746-5500 | blackbox.com
Page 33
After selecting the configuration file, the file upload process begins; when
completed, the user is notified of the status and also notified that a reboot is
necessary for the new configuration to become active:
By design, the IP Address configuration currently on the device is kept intact
and not overwritten by the new configuration file.
3.7 RJ-45 Data Port Pinout
The following table lists the pin
configuration for the RJ-45 Data
connector.
Pin
Signal
Name
1000M
Signal
Direction
10/100M
1 TXD1+ Out*
2 TXD1-
Out*
3 RXD2+ In*
4 D3+
5 D3-
6 RXD2-
In*
7 D4+
8 D4-
NOTE
The MDI/MDIX function will automatically adjust the direction of these signals to match
the connected unit when running 10/100Base-T. 1000Base-T will use all 4 pairs in full
duplex mode.
Pin 1