SCSI Fiber Optic Extender
Figure 3-2. Remove Four Bottom-Panel Screws to Access the PCB.
3.5 Connecting to the SCSI Bus
The SCSI Fiber Optic Extender provides a transparent, optically isolated
SCSI bus over extended distances, so you can install the Extender at any
point on your SCSI bus. Terminators must be installed on both the local
and extended bus, so make sure that a maximum of two terminators are
installed on each side of the Extender link (see
Figures 2-1
and
2-2
).
Connect the twisted-pair cable from the host or SCSI peripheral to the
50-pin SCSI connector on back of the Extender. Use the bail-locking
mechanism to anchor the connection securely.
N O T E
If external termination is required, be sure to remove the internal termination
networks and replace them with an internal terminator fuse F2 (included).
(See Figures 3-2. and 3-3.).