11 POP-UP INSTALLATION
Install and adjust Pop-Up (11A) using separate instructions supplied with the
Pop-Up assembly.
12 UNIT START UP
Turn on hot and cold water supplies, and check for leaks above and below
the sink.
14 SPRAY OPERATIONS
This pull-out faucet features two modes of operation: aeration mode and spray
mode. To switch to spray mode, rotate the Sprayhead (14A) in a clockwise
direction while the sprayhead is docked in the Faucet Spout (14B). To return to
aeration mode, rotate the Sprayhead in a counterclockwise direction.
15 PULL-OUT OPERATION
This faucet features a pull-out operation to spay water in any direction. Pull
the Sprayhead (15A) down and forward to retract the Hose (15B) from the
Spout (15C).
DRAIN BODY INSTALLATION
FAUCET FUNCTION
13 VALVE FUNCTION
COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-
clockwise, open-counterclockwise. The Spout (13A) can be rotated around
the Faucet Body in any direction.
Note: Flush faucet before turning on valve (see step 17).