E
N
G
L
IS
H
ENGLISH
16
17
18
19
16 REMOVING QUICK CONNECT
Turn off water supplies and relieve pressure before working on your faucet.
To remove the quick connect attachment: push up on the Quick Connect Housing
(16A). Holding plastic Collet (16B) in place, pull downward on Quick Connect
Housing (16A) until Tube (16C) is free.
MAINTENANCE & CARE
17 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (17A). Turn Valves (17B)
on and allow both hot and cold water to run for at least one minute each. While
water is running, check for leaks. To clean the aerator, disassemble Aerator
Housing (17A) by separating Switch Plate (17D) Washer (17B) and Basket
(17C) from Aerator Housing (17A). Once parts have been cleaned, reassemble
by reversing steps.
18 HANDLE REMOVAL
Turn off water before proceeding! With valves in closed position, detach
Decorative Button (18A), unscrew Fastener (18B), and remove Handle Hub
(18C) from Valve Stem (18D).
19 VALVE CARTRIDGE MAINTENANCE
Turn off water supplies and relieve pressure before working on your faucet.
Remove handles (See step 18), unscrew Cartridge Assembly (19A) and inspect.
Replace parts as necessary. Reassemble parts by reversing steps.
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfi ster.com
• Installation Support
• Care and Warranty Information
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased your
faucet.
2. When replacement parts are not available, please write or call Price Pfi ster
Consumer Service.
3. Always turn off water and relieve pressure before working on your faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative fi nishes, use only a soft damp cloth to clean and
shine. Use of polish, detergents, abrasive cleaners, organic solvents or acid may
cause damage. Use of other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar substance are not acceptable
for public areas or Commercial use. Installation of Said Trim is at Users Risk!
5
ENGLISH
16A
16A
16B
16C
17A
17D
17B
17C
17A
18A
18B
18C
18D
19A
17B